JLG 400SJ Operation And Safety Manual page 127

Table of Contents

Advertisement

4. Push in the Emergency Switch once the engine stops.
5. Disconnect the electrical connection to the LPG fuel
temperature sensor in the auxiliary fuel port of the EPR.
3121216
SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
NOTE: Have a small container ready to collect oil that will drain
– JLG Lift –
6. Remove the retainer clip for the LPG fuel temperature
sensor and remove the sensor from the regulator body.
freely from the regulator at this point.
7. Once all of the oil has been drained, reinstall the LPG
fuel temperature sensor and reconnect the electrical
connector.
8. Open the fuel tank manual valve.
9. Start the engine and verify all connections are secure.
10. Dispose of any drained oil per local regulations in a safe
and proper fashion.
6-35

Advertisement

Table of Contents
loading

This manual is also suitable for:

400s

Table of Contents