7. Suction Strainers
Lube Point(s) - 2
Interval - Every 2 years or 1200 hours of operation,
remove and clean at time of hydraulic oil change.
8. Oil Change w/Filter - Ford
Lube Point(s) - Fill Cap/Spin-on Element (JLG P/N
7014501)
Capacity - 4.5 qt. (4.25 L)
Lube - EO
Interval - 3 Months or 150 hours of operation
Comments - Check level daily/Change in accordance
with engine manual.
3121216
SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
– JLG Lift –
9. Oil Change w/Filter - Deutz
Lube Point(s) - Fill Cap/Spin-on Element (JLG P/N
7016331)
Capacity - 6.3 qt. (5.9 L) engine only
Lube - EO
Interval - Every Year or 1200 hours of operation
Comments - Check level daily/Change in accordance
with engine manual.