The options on the Data Fields window determine the data manipulation operations performed
by the encoder prior to reporting the data to the access control system.
The data read from the card can be split into multiple fields, each with its own conversion
operation.
6. Click Add Field. A new field row is listed. Each field has the following options:
7. Click Next.
Field
Field
Data Type
Start
Card Data Length
Data Representation
July 2017
Description
Names the Data Field and is auto-incremented when selecting Add Field. It is
recommended this name be left at its default setting.
Determines how the encoder is to interpret and convert the data in the field.
The following options are supported in the encoder:
Raw Data - no conversion
Binary Hex / Integer
BCD Nibble
BCD Byte
ASCII Decimal
ABA Track II as String
Specifies the starting bit number in the data field. Combined with the Card Data
Length field (specified in bits), it defines the actual data in the data field that is
to be manipulated and reported to the access control system. This is not the
same as the Data Offset parameter set on the previous page.
Default value of 0.
See description above (Start). Default value of 0.
Allows the reversal of the order of bytes before applying the conversion
specified in the Data Type field.
Options are: None, and ByteReversed.