Seos: Reading A Seos Data Object From A Custom Adf - HID CP1000 User Manual

Asure id iclass se desktop encoder
Table of Contents

Advertisement

Page 6-48
6.5.6

Seos: Reading a Seos Data Object from a Custom ADF

1. Select the Seos technology type. Click OK.
2. The Work Instruction Wizard opens to allow you to configure the Work Instruction for Prox.
Click Next.
3. Configure Seos Instruction Mode: You can make selections from the following. Click Next.
Field
Data Type
Instruction Type
Options
ADF Configuration
Read Configuration
PLT-01067, Version: A.7
Description
For this example Custom must be selected.
For this example Read must be selected.
Not available with Custom.
ADF OID: A number (8 byte minimum) used to reference the application
after it is created.
Show OID using ASCII characters: Displays ASCII characters.
Custom Read Key: Specify the Custom Read Key which will be used to
authenticate to the ADF to read the Data Object.
Note: If the desired key is not defined, select <Create New Key> from the
drop-down menu.
Read Key ID: This Read Key is to be referenced in the ADF.
Work Instruction Wizard