System Security
The System Security is disabled. The system administrator
name and system administrator passphrase are not set. All
computers on the trusted network can access the
configuration pages.
SOHO 6 Wireless Remote Management is disabled.
VPN Manager Access is disabled.
The remote logging is not configured.
WebBlocker
The WebBlocker is disabled and the settings are not
configured.
Upgrade Options
The upgrade options are disabled until the license keys are
entered into the configuration page.
Reset the SOHO 6 Wireless to the factory default
settings
Reset the SOHO 6 Wireless to the factory default settings if it is not
possible to correct a configuration problem. A reset to the factory
default settings is required if the system security passphrase is
unknown or the firmware of the SOHO 6 Wireless is damaged by a
power interruption. Follow these steps to reset the SOHO 6
Wireless to the factory default settings:
1
Disconnect the power supply.
2
Press and hold the reset button.
3
Connect the power supply.
4
Continue holding the button until the red LED on the front of
the SOHO 6 Wireless goes on and then off.
5
Disconnect the power supply.