Uponor Smatrix Base Installation And Operation Manual page 25

Hide thumbs Also See for Smatrix Base:
Table of Contents

Advertisement

Schedules
Programmable schedules can, during heating and/or
cooling, switch between Comfort and ECO mode. See
example below.
Schedule 1
Comfort
ECO
night
morning
0 h 00
6 h 00
12 h 00
Other rooms can, depending on system setup,
simultaneously switch between Comfort and ECO mode
according to their own programmed schedules.
This requires one or more of the following:
Uponor Smatrix Base PRO Interface I-147 (Base
PRO only)
The interface allows individual programmed
schedules for the rooms in the system. Any other
devices with its own programmed schedules are
overridden and its menus hidden.
Uponor Smatrix Base Timer I-143 (Base only)
The timer applies the schedule program to the
whole system. For the timer to control the digital
thermostat T-148, it is required that the thermostat
program is set to Off.
Uponor Smatrix Base Thermostat Prog.+RH T-148
The thermostat is in control of its own room, with
restrictions stated above, regarding the interface
and timer.
Schedule 2
Comfort
ECO
night
morning
0 h 00
6 h 00
12 h 00
U P O N O R S M AT R I X B A S E / B A S E P R O · I N S TA L L AT I O N A N D O P E R AT I O N M A N U A L
afternoon
night
18 h 00
24 h 00
afternoon
night
18 h 00
24 h 00
Even if programmed schedules exist in the system, some
rooms may still operate without any scheduling. These
rooms will operate in constant Comfort mode and is not
affected by the programming of other rooms.
Room sensor T-141:
Set the value in the Base PRO interface I-147.
Public thermostat T-143:
Set the switch on its back to comfort mode only.
Standard thermostat T-145:
Set the switch on its back to comfort mode only.
Digital thermostats T-146, and T-149:
Set the ECO setback value in menu 03 to 0.
Digital thermostat T-148:
Set the ECO setback value in menu 03 to 0 and
menu 00 to Off.
Heating/cooling switch
The heating/cooling switch is manually controlled
through an external signal to the controller. It is used to
switch the operation of the controller between heating
and cooling modes.
UK
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SK
2 5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smatrix base pro

Table of Contents