Uponor Smatrix Base PRO Quick Manuals
Uponor Smatrix Base PRO Quick Manuals

Uponor Smatrix Base PRO Quick Manuals

Hide thumbs Also See for Smatrix Base PRO:

Advertisement

Uponor Smatrix
Base PRO
E N Q U I C K G U I D E
10 | 2017

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Smatrix Base PRO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Uponor Smatrix Base PRO

  • Page 1 Uponor Smatrix Base PRO E N Q U I C K G U I D E 10 | 2017...
  • Page 2: Table Of Contents

    QUICK GUIDE Contents Uponor Smatrix Base PRO components Uponor Smatrix Base PRO components .......2 An Uponor Smatrix Base PRO system may be a System example ..............2 combination of the following components: Safety instructions ............3 • Uponor Smatrix Base PRO Controller X-147 Controller ................3...
  • Page 3: Safety Instructions

    Controller be done before registering a system device. N O T E ! arning The Uponor system uses 50 Hz, 230 V AC Up to 16 controllers can be registered to an power. In case of emergency, immediately interface. disconnect the power.
  • Page 4 QUICK GUIDE 1 . 2 1 . 1 1 . 2 1 . 2 1 . 1 1 . 1 1 . 2 1 . 1 X-147 M-140* X-147 M-140* 3 . 3 4 . 2 M-141* 2 . 2 3 .
  • Page 5: Quick Guide

    QUICK GUIDE 11.5 T-148 T-148 T-148 X-147 T-146 T-146 T-149 T-149 T-146 T-149 11.3 11.1 11.2 11.2 11.4 11.4 Quick Guide 9. Connect optional external sensor (compatible thermostats only) and set the DIP switch (public thermostat T-143 only). Installation Switch Function* 1.
  • Page 6 QUICK GUIDE T-149 T-148 T-146 T-145 T-144 T-143 T-141 13.1 13.2 13.3 13.1 T-143 T-149 T-144 T-146 T-148 T-141 T-145 13.1 I-147 16.1 16.2 T-143 16.3 16.4 I-147 T-143 17.2 17.1 16.3 Italiano Français Svenska Deutsch English Português Suomi Español Link Touch Screen to controller 17.3 Link OK...
  • Page 7: Es Register Thermostat And/Or System Device To A

    QUICK GUIDE Register thermostat and/or system device Register a system device (I-147 etc) to a controller N O T E ! To register room thermostats and system devices (interface At least one thermostat must be registered before etc.) to the controller: registering a system device.
  • Page 8: Register Multiple Controllers

    QUICK GUIDE Register multiple controllers Unregister all channels Up to 16 controllers can be registered to an interface. When one or more channels are inaccurately registered, it is possible to remove all registrations at the same All additional controllers in the system must be time.
  • Page 9: Technical Data

    QUICK GUIDE Technical data General IP20 (IP: degree of inaccessibility to active parts of the product and degree of water) Max. ambient RH (relative humidity) 85% at 20 °C Thermostat CE marking ERP (thermostat only) Low voltage tests EN 60730-1* and EN 60730-2-9*** EMC (electromagnetic compatibility requirements) tests EN 60730-1 Power supply...
  • Page 10 Uponor Corporation www.uponor.com Uponor reserves the right to make changes, without prior notification, to the specification of incorporated components in line with its policy of continuous improvement and development.

Table of Contents