Uponor Smatrix Base Installation And Operation Manual page 116

Hide thumbs Also See for Smatrix Base:
Table of Contents

Advertisement

UK
Problem
The room is too
CZ
warm
(or too cold in
cooling mode)
DE
The floor is cold
DK
All rooms are cold
(or warm in cooling
EE
mode)
ES
FI
FR
Disturbing noise
from the pump at
the same time and
HR
day of the week
No communication
HU
IT
Communication
failure between the
LT
controllers
LV
Frozen display in
the interface
NL
NO
PL
PT
RO
RU
SE
SK
1 1 6
Indication
Corresponding loop is warm even after a
long period without heat call
The room temperature OK but the floor
is cold
Holiday mode
ECO mode for rooms in timer or digital
thermostat T-148
Check the chiller (boiler) information and
operation mode of the thermostats
Communication error
Software versions incompatible
Communication error
No response when pressing a button
Probable cause
An actuator does not close
No heat demand from the underfloor
heating system
The room is heated by another heat
source
Icon displayed in the interface (if
installed, Base PRO only) or timer
(Base only)
ECO mode
The system is in cooling (heating)
mode
Registration lost
Registration to controller is lost
General failure
U P O N O R S M AT R I X B A S E / B A S E P R O · I N S TA L L AT I O N A N D O P E R AT I O N M A N U A L
Solutions
Contact the installer
Check that the actuator is correctly
installed
Replace the actuator
Cancel Holiday mode
Change ECO profile or assign another
profile to the room/system
Reduce the ECO setback value for the
thermostats
Reduce the General ECO setback value in
the interface (if installed, Base PRO only)
or timer (Base only)
Correct signal from external device needed
Change time for pump exercise (requires
Base PRO with interface I-147)
Contact the installer
Check registration status of the interface
and the controller (if installed, Base PRO
only)
Register the interface again (if installed,
Base PRO only)
Contact the installer
Check the registration status of the
interface and controller
Check the controller configuration
Check the wiring
Restart the interface (power off the
interface, wait about 10 seconds and
power it on again)