5.6.4 TABLE 1
5.6 Alarm
1.
Output 1
2.
Output 2
3.
Table
4.
Table 1
1
Type of alarm alert
Lamp
Speaker
2
Time
3
Symbol for alarm of boiler errors.
4
Symbol for alarm of fuel level
warning
5
Signal type of boiler erros alarm.
6
Signal type of fuel level warning
Setting values on table 1
Using the table to turn on or of and change type of signal for alarm or low fuel level warning at different
times and days. When you enter the editing table, it is necessary to press 2 times the desired box (day)
and then opens a new window where you can turn on and off, set signal type for boiler error, fuel level
warning and the time at which the selected signal type takes effect. Eg. to change the time, it is
necessary to press the box with time. When pressed on the box with time, its background becomes
white and then it is possible to change the parameters by pressing the ''up'' and'' down'' (
It is possible to specify the type of signal 16 changes per day.
On the next page are described all symbols for types of signal. In the same way, you can fill table
2 (table 3 is not used).
The type of connected device (lamp or speaker) can be set only in installation
menu, only by an authorized person.
Technical instructions REGULATION PelTec / PelTec-lambda
5.
Table 2
6.
Table 3
MON
TUE
00:00
1
2
3
4
1
5
6
Alarm - Table 1
MON
TUE
WED
00:00
1
2
2X
3
4
5
6
Alarm - Table 1
WED
FRI
THU
06:00
2
3
4
5
6

Alarm (table)

FRI
SAT
SUN
THU
SAT
SUN
PON 2
).
63