Trouble Shooting - IDTECK GE313 Operating Manual

Table of Contents

Advertisement

B. TROUBLE SHOOTING
☞ When the power off and on after the time setting, the LCD displays "00/00 00:00:01".
Cause
Of that user mistake, or the system is defective of the device.
Solution
1. Check BAT connection S/W.
You have to short the S/W, and system initialize before system installation.
2. If the trouble remains after checking the above, contact a designated service center.
☞ A valid card became unregistered after batch-downloading IDs from PC.
Cause
Wrong procedure during download or a component defect.
Solution
1. The card ID might be registered only to the controller and not registered in the PC. During the process
of downloading IDs, GE313 first erase the ID memory of the unit, therefore if the IDs from the PC
didn't contain the card ID, this can happen.
2. Check whether the card ID is registered in the PC.
3. If not, please register the number and try downloading again.
4. If the trouble remains after the procedure above, contact a designated service center.
☞ It doesn't enter the Setup Mode after entering the Master ID "00000000".
Cause
The Master ID might have been changed or components are defective.
Solution
1. Try changing the Master ID through the application S/W (It'll be changed to "00000000").
2. When it is not feasible, initialize the unit as following:
After the all installation and connections are completed, press and hold the Initialize button and put the
power (+12V DC) to GE313. The LCD will first display "Initialize OK? 0:No 1:Yes". Press <1> key
if you want to initialize the system. After all Initialization process is completed, the system is operating
on normal mode and the LCD displays "GE Security, GE313 [F1], Date Time".
3. If the trouble remains after the procedure above, contact a designated service center.
Figure: SWITCH SETTING
Figure: SWITCH LOCATION
60

Advertisement

Table of Contents
loading

Table of Contents