Table B–10: MODBUS MEMORY MAP (Sheet 11 of 64)
ADDR
REGISTER NAME
2548
Remote Double-point Status Input 1 Events
2549
... Repeated for Remote Double-point Status Input
2
2552
... Repeated for Remote Double-point Status Input
3
255B
... Repeated for Remote Double-point Status Input
4
2564
... Repeated for Remote Double-point Status Input
5
IEC 61850 GGIO5 Configuration (Read/Write Setting Registers) (16 modules)
26D0
IEC 61850 GGIO5 uinteger Input 1 Operand
26D1
IEC 61850 GGIO5 uinteger Input 2 Operand
26D2
IEC 61850 GGIO5 uinteger Input 3 Operand
26D3
IEC 61850 GGIO5 uinteger Input 4 Operand
26D4
IEC 61850 GGIO5 uinteger Input 5 Operand
26D5
IEC 61850 GGIO5 uinteger Input 6 Operand
26D6
IEC 61850 GGIO5 uinteger Input 7 Operand
26D7
IEC 61850 GGIO5 uinteger Input 8 Operand
26D8
IEC 61850 GGIO5 uinteger Input 9 Operand
26D9
IEC 61850 GGIO5 uinteger Input 10 Operand
26DA
IEC 61850 GGIO5 uinteger Input 11 Operand
26DB
IEC 61850 GGIO5 uinteger Input 12 Operand
26DC
IEC 61850 GGIO5 uinteger Input 13 Operand
26DD
IEC 61850 GGIO5 uinteger Input 14 Operand
26DE
IEC 61850 GGIO5 uinteger Input 15 Operand
26DF
IEC 61850 GGIO5 uinteger Input 16 Operand
IEC 61850 Received Integers (Read Only Actual Values) (16 modules)
26F0
IEC 61850 Received uinteger 1
26F2
IEC 61850 Received uinteger 2
26F4
IEC 61850 Received uinteger 3
26F6
IEC 61850 Received uinteger 4
26F8
IEC 61850 Received uinteger 5
26FA
IEC 61850 Received uinteger 6
26FC
IEC 61850 Received uinteger 7
26FE
IEC 61850 Received uinteger 8
2700
IEC 61850 Received uinteger 9
2702
IEC 61850 Received uinteger 10
2704
IEC 61850 Received uinteger 11
2706
IEC 61850 Received uinteger 12
2708
IEC 61850 Received uinteger 13
270A
IEC 61850 Received uinteger 14
270C
IEC 61850 Received uinteger 15
270E
IEC 61850 Received uinteger 16
Expanded FlexStates (Read Only)
2B00
FlexStates, one per register (256 items)
Expanded Contact Input/Output States (Read Only)
2D00
Contact Input States, one per register (96 items)
2D80
Contact Output States, one per register (64 items)
2E00
Virtual Output States, one per register (96 items)
Expanded Remote Input/Output Status (Read Only)
2F00
Remote Device States, one per register (32 items)
GE Multilin
RANGE
0 to 1
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
B30 Bus Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F155
DEFAULT
0 (Disabled)
B
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Offline)
B-19