B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 20 of 64)
ADDR
REGISTER NAME
3FA9
...Repeated for Field Unit Transducer 8
Field Unit Identifiers (Read Only) (8 modules)
3FB8
Attached Field Unit 1 Serial Number
3FBE
Attached Filed Unit 1 Port Number
B
3FBF
Attached Field Unit 1 Type
3FC0
Field Unit 1 Status
3FC1
...Repeated for Field Unit 2
3FCA
...Repeated for Field Unit 3
3FD3
...Repeated for Field Unit 4
3FDC
...Repeated for Field Unit 5
3FE5
...Repeated for Field Unit 6
3FEE
...Repeated for Field Unit 7
3FF7
...Repeated for Field Unit 8
Passwords (Read/Write Command)
4000
Command Password Setting
Passwords (Read/Write Setting)
400A
Setting Password Setting
Passwords (Read/Write)
4014
Command Password Entry
401E
Setting Password Entry
Passwords (Read Only)
4028
Command Password Status
4029
Setting Password Status
Passwords (Read/Write Setting)
402A
Command Password Access Timeout
402B
Setting Password Access Timeout
402C
Invalid Password Attempts (before lockout)
402D
Password Lockout Duration
Passwords (Read/Write)
402E
Password Access Events
Passwords (Read/Write Setting)
402F
Local Setting Auth
4031
Remote Setting Auth
4033
Access Auth Timeout
User Display Invoke (Read/Write Setting)
4040
Invoke and Scroll Through User Display Menu
Operand
LED Test (Read/Write Setting)
4048
LED Test Function
4049
LED Test Control
Preferences (Read/Write Setting)
404F
Language
4050
Flash Message Time
4051
Default Message Timeout
4052
Default Message Intensity
4053
Screen Saver Feature
4054
Screen Saver Wait Time
4055
Current Cutoff Level
4056
Voltage Cutoff Level
B-28
RANGE
---
---
0 to 3
0 to 4
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
5 to 480
5 to 480
2 to 5
5 to 60
0 to 1
1 to 4294967295
0 to 4294967295
5 to 480
0 to 4294967295
0 to 1
0 to 4294967295
0 to 5
0.5 to 10
10 to 900
0 to 3
0 to 1
1 to 65535
0.002 to 0.02
0.1 to 1
B30 Bus Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F205
---
1
F001
---
1
F243
---
1
F262
---
1
F202
---
1
F202
---
1
F202
---
1
F202
---
1
F102
---
1
F102
min
1
F001
min
1
F001
---
1
F001
min
1
F001
---
1
F102
---
1
F300
---
1
F300
min
1
F001
---
1
F300
---
1
F102
---
1
F300
---
1
F531
s
0.1
F001
s
1
F001
---
1
F101
---
1
F102
min
1
F001
pu
0.001
F001
V
0.1
F001
DEFAULT
(none)
0
0 (CC-05)
0 (Disabled)
(none)
(none)
(none)
(none)
0 (Disabled)
0 (Disabled)
5
30
3
5
0 (Disabled)
1
1
30
0
0 (Disabled)
0
0 (English)
10
300
0 (25%)
0 (Disabled)
30
20
10
GE Multilin