GE B30 Instruction Manual page 453

Ur series bus differential system protection relay
Hide thumbs Also See for B30:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 5 of 64)
ADDR
REGISTER NAME
06E4
...Repeated for Binary Input 89
06E8
...Repeated for Binary Input 90
06EC
...Repeated for Binary Input 91
06F0
...Repeated for Binary Input 92
06F4
...Repeated for Binary Input 93
06F8
...Repeated for Binary Input 94
06FC
...Repeated for Binary Input 95
0700
...Repeated for Binary Input 96
IEC 103 ASDU Settings (Read/Write Setting) (4 modules)
0704
IEC103 ASDU1 TYP
0705
IEC103 ASDU 1 FUN
0706
IEC103 ASDU 1 INF
0707
IEC103 ASDU 1 Scan Timeout
0708
IEC103 ASDU 1 Analog Param 1
0709
IEC103 ASDU 1 Analog Factor 1
070A
IEC103 ASDU 1 Analog Offset 1
070B
IEC103 ASDU 1 Analog Param 2
070C
IEC103 ASDU 1 Analog Factor 2
070D
IEC103 ASDU 1 Analog Offset 2
070E
IEC103 ASDU 1 Analog Param 3
070F
IEC103 ASDU 1 Analog Factor 3
0710
IEC103 ASDU 1 Analog Offset 3
0711
IEC103 ASDU 1 Analog Param 4
0712
IEC103 ASDU 1 Analog Factor 4
0713
IEC103 ASDU 1 Analog Offset 4
0714
IEC103 ASDU 1 Analog Param 5
0715
IEC103 ASDU 1 Analog Factor 5
0716
IEC103 ASDU 1 Analog Offset 5
0717
IEC103 ASDU 1 Analog Param 6
0718
IEC103 ASDU 1 Analog Factor 6
0719
IEC103 ASDU 1 Analog Offset 6
071A
IEC103 ASDU 1 Analog Param 7
071B
IEC103 ASDU 1 Analog Factor 7
071C
IEC103 ASDU 1 Analog Offset 7
071D
IEC103 ASDU 1 Analog Param 8
071E
IEC103 ASDU 1 Analog Factor 8
071F
IEC103 ASDU 1 Analog Offset 8
0720
IEC103 ASDU 1 Analog Param 9
0721
IEC103 ASDU 1 Analog Factor 9
0722
IEC103 ASDU 1 Analog Offset 9
0723
...Repeated for IEC103 ASDU 2
0742
...Repeated for IEC103 ASDU 3
0761
...Repeated for IEC103 ASDU 4
IEC 103 Commands (Read/Write Setting) (32 modules)
0780
IEC103 Command 1 FUN
0781
IEC103 Command 1 INF
0782
IEC103 Command 1 Param ON
0783
IEC103 Command 1 Param OFF
0784
...Repeated for IEC103 Command 2
GE Multilin
RANGE
0 to 1
0 to 255
0 to 255
0 to 1000
0 to 65535
0 to 65.535
-32768 to 32767
0 to 65535
0 to 65.535
-32768 to 32767
0 to 65535
0 to 65.535
-32768 to 32767
0 to 65535
0 to 65.535
-32768 to 32767
0 to 65535
0 to 65.535
-32768 to 32767
0 to 65535
0 to 65.535
-32768 to 32767
0 to 65535
0 to 65.535
-32768 to 32767
0 to 65535
0 to 65.535
-32768 to 32767
0 to 65535
0 to 65.535
-32768 to 32767
0 to 255
0 to 255
0 to 64
0 to 64
B30 Bus Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F630
---
1
F001
---
1
F001
---
1
F001
---
1
F600
---
0.001
F001
---
1
F002
---
1
F600
---
0.001
F001
---
1
F002
---
1
F600
---
0.001
F001
---
1
F002
---
1
F600
---
0.001
F001
---
1
F002
---
1
F600
---
0.001
F001
---
1
F002
---
1
F600
---
0.001
F001
---
1
F002
---
1
F600
---
0.001
F001
---
1
F002
---
1
F600
---
0.001
F001
---
1
F002
---
1
F600
---
0.001
F001
---
1
F002
---
1
F001
---
1
F001
---
1
F631
---
1
F631
DEFAULT
B
1(9)
0
0
0
0
1000
0
0
1000
0
0
1000
0
0
1000
0
0
1000
0
0
1000
0
0
1000
0
0
1000
0
0
1000
0
0
0
0 (OFF)
0 (OFF)
B-13

Advertisement

Table of Contents
loading

Table of Contents