GE B30 Instruction Manual page 480

Ur series bus differential system protection relay
Hide thumbs Also See for B30:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 32 of 64)
ADDR
REGISTER NAME
5DA2
Ground Instantaneous Overcurrent 1 Pickup
5DA3
Ground Instantaneous Overcurrent 1 Delay
5DA4
Ground Instantaneous Overcurrent 1 Reset Delay
5DA5
Ground Instantaneous Overcurrent 1 Block
B
5DA7
Ground Instantaneous Overcurrent 1 Target
5DA8
Ground Instantaneous Overcurrent 1 Events
5DA9
Reserved (8 items)
5DB1
...Repeated for Ground Instantaneous Overcurrent
2
5DC2
...Repeated for Ground Instantaneous Overcurrent
3
5DD3
...Repeated for Ground Instantaneous Overcurrent
4
5DE4
...Repeated for Ground Instantaneous Overcurrent
5
5DF5
...Repeated for Ground Instantaneous Overcurrent
6
Setting Groups (Read/Write Setting)
5F70
Setting Group for Modbus Comms (0 means group
1)
5F71
Setting Groups Block
5F73
FlexLogic Operands to Activate Groups 2 through
6 (5 items)
5F7D
Setting Group Function
5F7E
Setting Group Events
Setting Groups (Read Only)
5F7F
Current Setting Group
Setting Group Names (Read/Write Setting)
5F8C
Setting Group 1 Name
5F94
Setting Group 2 Name
5F9C
Setting Group 3 Name
5FA4
Setting Group 4 Name
5FAC
Setting Group 5 Name
5FB4
Setting Group 6 Name
Bus Configuration (Read/Write Setting) (2 modules)
64B0
Bus Zone xA Source (6 items)
64B6
Bus Zone xA Status (6 items)
64C2
...Repeated for Bus Zone 2
Bus Differential (Read/Write Grouped Setting) (4 modules)
64E0
Bus Zone 1 Function
64E1
Bus Zone 1 Pickup
64E2
Bus Zone 1 Low Slope
64E3
Bus Zone 1 Low Breakpoint
64E4
Bus Zone 1 High Slope
64E5
Bus Zone 1 High Breakpoint
64E6
Bus Zone 1 High Set
64E7
Bus Zone 1 Seal In
64E8
Bus Zone 1 Block
64EA
Bus Zone 1 Events
64EB
Bus Zone 1 Target
64F8
...Repeated for Bus Zone 2
6510
...Repeated for Bus Zone 3
B-40
RANGE
0 to 30
0 to 600
0 to 600
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 5
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
0 to 5
---
---
---
---
---
---
0 to 5
0 to 4294967295
0 to 1
0.05 to 6
15 to 100
1 to 30
50 to 100
1 to 30
0.1 to 99.99
0 to 65.535
0 to 4294967295
0 to 1
0 to 2
B30 Bus Differential System
APPENDIX B
UNITS
STEP
FORMAT
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F001
---
1
F300
---
1
F300
---
1
F102
---
1
F102
---
1
F001
---
---
F203
---
---
F203
---
---
F203
---
---
F203
---
---
F203
---
---
F203
---
1
F167
---
1
F300
---
1
F102
pu
0.001
F001
%
1
F001
pu
0.01
F001
%
1
F001
pu
0.01
F001
pu
0.01
F001
s
0.001
F001
---
1
F300
---
1
F102
---
1
F109
DEFAULT
1000
0
0
0
0 (Self-reset)
0 (Disabled)
0
0
0
0
0 (Disabled)
0 (Disabled)
0
(none)
(none)
(none)
(none)
(none)
(none)
0 (SRC 1)
0
0 (Disabled)
100
25
200
60
800
1500
400
0
0 (Disabled)
0 (Self-reset)
GE Multilin