PLT-03159, Rev A.0
Field
Mag Lo-Co Voltage
Offset
Ribbon Green LED
Level
Ribbon Blue LED Level
Erase Heat Offset
Write Heat Offset
Flipper Home Offset
Flipper Eject Height
Offset
Mag Super-Co Voltage
Offset
Mag Medium-Co
Voltage Offset
Head Home Offset
Head Print Offset
September 2017
Description
This setting is a calibration driven value and should not be adjusted.
It is factory set and should not be changed unless directed by a technician.
This setting is a calibration driven value and should not be adjusted.
It is factory set and should not be changed unless directed by a technician.
This setting is a calibration driven value and should not be adjusted.
It is factory set and should not be changed unless directed by a technician.
Adjust the temperature for the rewritable cards as needed.
Increase the current setting to cause more heat to be used in the erasing process.
OR
Decrease the current setting to cause less heat to be used in the erasing process.
Note: This setting provides the ability to control the printhead heat level when the
erase operation is performed. Appropriate heat levels should be applied for the
proper erase process. This setting should be adjusted for proper erasure.
Adjust the temperature for the rewritable cards as needed.
Increase the current setting to cause more heat to be used in the printing process
of a rewritable card.
OR
Decrease the current setting to cause less heat to be used in the printing process
of a rewritable card.
Note: This setting provides the capability to control the printhead heat level when
the write operation is performed. Appropriate heat levels should be applied for the
proper writing process.
This setting is a calibration driven value and should not be adjusted. If the flipper
unit is replaced and has not been calibrated, this value may need to be adjusted.
This setting is factory set and should not be changed unless directed by a
technician.
This setting is a calibration driven value and should not be adjusted. If the flipper
unit is replaced and has not been calibrated, this value may need to be adjusted.
This setting is factory set and should not be changed unless directed by a
technician.
This option changes the voltage going the magnetic head.
This setting is factory set and should not be changed unless directed by a
technician.
This option changes the voltage going the magnetic head.
This setting is factory set and should not be changed unless directed by a
technician.
This setting is a calibration driven value and should not be adjusted. If the
printhead assembly is replaced, then this value may need to be adjusted.
This setting is factory set and should not be changed unless directed by a
technician
This setting is a calibration driven value and should not be adjusted. If the
printhead assembly is replaced, then this value may need to be adjusted.
This setting is factory set and should not be changed unless directed by a
technician.