Return to Factory Setting
▶ This function is for return incubator to factory setting.
▶ Unplug power cord. Replug during
Then, "rSt AL" will indicated in display, and incubator
return to factory setting. (Default setting)
Temperature Setting
▶ Press
and
button at the same time then " tEP "
will be indicated for about 0.5sec. and then temp display
will blink.
▶ When temperature indicator flickers, press
button each to increase or decrease temperature
to 0.1℃ level. [Default setting : 26.1℃ (78.98℉)]
▶ In case of pressing
value, temperature value is saved and "HI" is displayed
(abnormal high temperature alarm) as a next step at
temperature display window for 0.5 seconds and its set
value flickers.
※ In case of not wanting to change setting, press
When releasing from the factory, temperature was corrected to be optimized according to international
standard. If necessary, recorrection is possible, however, it isn't desirable for users to correct it directly.
In case that correction is necessary, please contact Rcom homepage (www.Rcom.co.kr→data center →
Instruction manual categoty) or place where you purchased to inquire about it. As low price thermometer and
hygrometer easy to purchase in the open market have much deviation of estimate value, it is desirable to
use corrected thermometer and hygrometer for exclusive use. [thermometer and hygrometer for exclusive
use – See Rcom homepage]
DIGITAL INCUBATOR
4. Function Settings
button is pressed.
button or
button after changing into wanted
HOLD
Factory Setting Display
Step 1
Step 2
button to go to the next step.
(1) Return to Factory Settion
(2) Temperature Setting
Power Cord
11