Return to Factory Settings
▶ This function is for return machine to factory setting.
▶ Unplug power cord. Reconnect power plug whilst
simultaneously pressing the jog dial. Then, "rSt AL" will
be indicated in the display, now the MARU is returned to
factory settings. (Default setting)
Temperature Settings
▶ When jog dial is pressed for 3 seconds from the initial
setting, "tEP" (Temperature) is displayed for 0.5 seconds
and the temperature setting will blink.
▶ When the temperature setting is blinking, turn the jog dial
to left or right to increase or decrease the temperature
by 0.1°C. [Default Value: 37.0
▶ When the desired setting is reached, press the jog dial
once to save the set temperature value, now next phase,
humidity setting's "rH" (humidity), will display for 0.5
seconds on the display window and the set value will blink.
※ If you do not wish to change the setting values for the remaining functions in the next steps, press the jog dial for
3 second and the standard values will be entered , the SET display and menu will discontinue.
Humidity Settings and Humidifier Device OFF method
▶ From the temperature setting, press the jog dial once and
"rH" (Humidity) will be displayed for 0.5 second and humidity
display will blink.
▶ When the humidity display blinks, turn the jog dial left or
right to increase or decrease the humidify by 1%.
[Default Value: RH 60%]
▶ If, when the humidify display is blinking, and you set the
RH below 20%, (set by turning the jog dial to the left), the
humidity function will now be "OFF" and will be displayed
as ⓐ on the display panel.
▶ When the desired setting is reached, press the jog dial once
to save the set humidity value and sequence will move to
the next phase i.e Abnormal High Temperature alarm. "HI"
(Abnormal HIgh Temperature Alarm), will display for 0.5
seconds on the display window and the set value will blink.
The temperature and humidity level is optimized
according to the international standard at the time of
shipping. It could be recalibrated by the user if the user
wishes to do so, but this is not recommended.
When in need of adjustment, please refer to our homepage (www.Rcom.co.kr → Information → User Manual
Category) or contact the place of purchase. Commercially available thermometer and hygrometers may have
drastic measurement deviations, so it is recommended to use thermometer and hygrometer designated for
this purpose. [Designated Thermometer and hygrometer – Refer to Rcom Homepage]
※ If you do not wish to change the setting values for the remaining functions in the next steps, press the jog dial for
3 second and the standard values will be entered , the SET display and menu will discontinue.
DIGITAL INCUBATOR
4. MARU H&B Function Settings
(98.6
)]
℃
℉
(1) Return to Factory Settings
(2) Temperature and Humidity Settings
Factory Setting Display
Step 1
Step 2
Step 3
Humidity Function OFF
Step 4
13
Need help?