DMD2050E Universal Satellite Modem
LOCAL AUPC MENU
MINIMUM TX POWER
MAXIMUM TX POWER
MN-DMD2050E Revision 2
{0 to -45 dB}
{0 to -45 dB}
Set the minimum Transmit Power.
EBEM: When configured for EBEM AUPC, the minimum
Transmit Power is the lowest power setting that will be used
when the remote modem commands a decrease of the
Transmit Power from the Local modem.
EFDATA AUPC: When configured for EFDATA AUPC the
minimum Transmit Power is the lowest power setting that will
be used when the local modem commands a decrease of the
Transmit Power from the Remote modem.
RADYNE: When configured for Radyne AUPC, the minimum
Transmit Power is the lowest power setting that will be used
when the remote modem commands a decrease of the
Transmit Power from the Local modem.
NEARSIDE: When configured for NEARSIDE AUPC the
minimum Transmit Power is the lowest power setting that will
be used by the local modem when the Eb/No increases
above the Eb/No target.
Set the maximum Transmit Power.
EBEM: When configured for EBEM AUPC, the maximum
Transmit Power is the highest power setting that will be used
when the remote modem commands an increase of the
Transmit Power from the Local modem
EF AUPC: When configured for EF AUPC, the maximum
Transmit Power is the highest power setting that the local
modem will use when the local modem commands an
increase in Transmit power from the Remote modem.
RADYNE: When configured for Radyne AUPC, the maximum
Transmit Power is the highest power setting that will be used
when the remote modem commands an increase of the
Transmit Power from the Local modem
NEARSIDE: When configured for NEARSIDE AUPC the
maximum Transmit Power is the highest power setting that
will be used by the local modem when the Eb/No decreases
below the Eb/No target.
User Interfaces
4–11
Need help?
Do you have a question about the DMD-2050E and is the answer not in the manual?
Questions and answers