JUKI SC-510 Engineer's Manual page 51

Hide thumbs Also See for SC-510:
Table of Contents

Advertisement

Parameter 2
Setting
range
Delay time (d.)
0 : Without delay
1 to 999 X 1mS
Delay time (d.)
0 : Without delay
1 to 999 X 1mS
Delay time (d.)
0 : Without delay
1 to 999 X 1mS
1 to 20
Angle (A.)
0 : Without delay
1 to 359 º
1 to 20
Angle (A.)
0 : Without delay
1 to 359 º
Delay time (d.)
0 : Without delay
1 to 999 X 1mS
on/off
Delay time (d.)
0 : Without delay
1 to 999 X 1mS
on/off
Delay time (d.)
0 : Invalid
1 to 999 X 1mS
1 to 4
Invalid
Setting range
UP position stop command (speed designated with other command
is neglected.)
Command is executed without delay time with delay time "0". For
others, UP position stop command is valid within set delay time
and command is invalid after lapse of delay time.
When command is executed, sewing machine rotates normally,
and needle goes to UP position when it is in DOWN position and
vice versa. Even if there is speed limitation with other command, it
is neglected.
Command is executed without delay time with delay time "0". For
others, command is valid within set delay time and command is
invalid after lapse of delay time.
When reverse rotation command is executed, sewing machine
brakes by reverse rotation from angle set in function setting No.
19 and stops. Command is executed without delay time with delay
time "0". For others, command is valid within set delay time and
command is invalid after lapse of delay time.
Step moves to next one after lapse of set angle, and when all input
conditions are completed (AND input), step moves to skip
destination step No. (Angle reference is angle from UP position
miss.)
Step moves to next one after lapse of set angle, and when either
one of input conditions is completed (OR input), step moves to
skip destination step No. (Angle reference is angle from UP position
miss.)
Stop command is output and step moves to next one. When time
is set, step moves to next one after lapse of set time.
On/off of reverse feed stitching switch is set.
Command is executed without delay time with delay time "0". For
other set value, command is executed after lapse of back-tack
output "on" time during set time.
On/off of presser lifting switch command is set.
Command is executed without delay time with delay time "0". For
other set value, presser lifting output "off" is executed after lapse
of presser lifting output "on" time during set time.
Initialization of step of designated program No. Step of designated
program is compulsorily returned to the first step.
46