Changing Procedure Of The Pedal Type - JUKI SC-510 Engineer's Manual

Hide thumbs Also See for SC-510:
Table of Contents

Advertisement

6. CHANGING PROCEDURE OF THE PEDAL TYPE

1. Standard state of the pedal type of SC-510 is PFL type.
2. Amount of depressing the back part of pedal to actuate thread trimmer is large (thread trimming position
is deep) since there is an auto-lifter section in case of PFL type of the standard state.
3. For this reason, when you feel that the work is hard, we recommend that you change over to KFL type
with the memory switch.
By setting to KFL type, when depressing the back part of pedal, thread trimming motion is performed at
a shallow position.
For changing procedure, follow (3) Setting for functions of SC-510, and change according to the description
below.
@4 Pedal presser lifting function (Function setting No. 50)
Pedal type setting can be changed. Selection of conventional PFL and KFL types can be selected.
5
0
Set value 1 : PFL is the standard. Amount of depressing the back part of pedal to actuate thread trimmer is
large (thread trimming position is deep) since there is an auto-lifter section in case of PFL type of the
standard state.
By setting to KFL type, when depressing the back part of pedal, thread trimming motion is performed at a
shallow position.
0 : Function is same as conventional KFL type.
0
1 : Function is same as conventional PFL type.
37