Operation
Display and control panel
Layout
Default View
Menu
Code: rH
22
4 digit Display divided into 2 sections: The rst 2 digits show the code and the last 2 show the
value of the code.
Code
By default the display will show the relative humidity RH %. This reading can be from the
external humidity/temperature sensor when available, if not the RH will be from the internal
humidity sensor.
OK
Press and hold OK button for 3 sec to enter menu mode
Toggle Menu Page
The Code is rH. The value can be set between 40 and 99 by
pressing the Up or Down key.
Default value is 60%RH. Follow these steps to change to the desired value:
1.
OK
2.
p
n
OK
3.
Value
Example
Press OK. The Value digits will ash.
Press the Up or Down key to the desired value. Note that
pressing and holding the Up or Down key will accelerate the
number increment to 5 per second.
Press OK to save the new value.
OK

Advertisement