Download Print this page

IAI SW-4000TL-PMCL Command List page 5

High speed cmos trilinear camera

Advertisement

BinningVertical
R/W
PixelFormat
R/W
TestImageSelector
R/W
AcquisitionControl
Name
Access Short ASCII
AcquisitionLineRate
R/W
TriggerMode
R/W
R/W
TriggerSource
TriggerActivation
R/W
ExposureMode
R/W
ExposureTime
R/W
AutoReset
R/W
AcquisitionLineRateMin
R/O
ExposureTimeMin
R/O
1: Binning Off
VB
2: Binning On
0:RGB8
BA
1:RGB10
0:Off
1:White
TPN
2:Gray Pattern 1 (Ramp)
3:Gray Pattern 2 (Stripe)
4:Color Bar
Values
LR
0: Off
TM
1: On
0:  Low
1:  High
10: PulseGenerator 0
11: PulseGenerator 1
12: PulseGenerator 2
13: PulseGenerator 3
14: UserOutput 0
15: UserOutput 1
16: UserOutput 2
TI
17: UserOutput 3
20:
Line4: TTL In1
21:  Line5: Opt In1
23:  Line7: :CC1
24:
Line10: TTL In2
26: NAND0Out
27: NAND1Out
28: Line13: TTL In3
29: EncoderTrigger
0: RisingEdge
1: FallingEdge
TA
2: LevelHigh
3: LevelLow
0: Off
TR
1: Timed
2: TriggerWidth
PE
300~1514908[us]
0: Off
ARS
1: On
LRMIN
PEMIN
VB=[Param.]<CR><LF>
VB?<CR><LF>
1
2
1
Set the number of pixels in the vertical direction for which
to perform binning.
BA=[Param.]<CR><LF>
BA?<CR><LF>
0
2
0
Set the pixel format.
TPN=[Param.]<CR><LF>
TPN?<CR><LF>
0
0
4
Select the test image.
MIN
MAX
DEFAULT Description
LR=[Param.]<CR><LF>
LR?<CR><LF>
1516
1515152
1515152
Use this command to set the line rate of the camera by
specifying the line period. The unit value is 1/100 µs.
Example: If you need 65963 Hz = 1516 (15.16 µs line
period).
TM=[Param.]<CR><LF>
TM?<CR><LF>
0
1
0
Display the Trigger mode.
TI=[Param.]<CR><LF>
TI?<CR><LF>
0
29
20
Select the trigger signal source.
TA=[Param.]<CR><LF>
TA?<CR><LF>
0
3
1
Select the polarity of the trigger signal(i.e., location of
signal at which trigger is applied).
TR=[Param.]<CR><LF>
TR?<CR><LF>
0
2
1
Select the exposure mode.
PE=[Param.]<CR><LF>
PE?<CR><LF>
300
1514908
27847
Set the exposure time.
ARS=[Param.]<CR><LF>
ARS?<CR><LF>
Set the AutoReset. (When auto reset mode is enabled,
0
1
0
LVAL, DVAL, and video are not output while the trigger
input is interrupted.
When resuming trigger input, output of LVAL, DVAL, and
video is resumed.)
LRMIN?<CR><LF>
-
-
-
Display the minimum value that can be set to
[AcquisitionLineRate].
PEMIN?<CR><LF>
-
-
-
Display the minimum value that can be set to
[ExposureTime].

Advertisement

loading