Download Print this page

IAI SW-4000TL-PMCL Command List page 11

High speed cmos trilinear camera

Advertisement

CounterValue[Counter0]
R/O
R/O
CounterValue[Counter1]
R/O
CounterValue[Counter2]
CounterValue[Counter3]
R/O
UserSetControl
Name
Access Short ASCII
UserSetLoad
R/W
UserSetSave
R/W
TranceportLayerControl
Access Short ASCII
Name
ClConfiguration
R/W
CameraLinkClockFrequency
R/W
SwapBandR
R/W
AdditionalInformation
R/W
ExposureActiveSource
R/W
PulseGenerators
Name
Access Short ASCII
ClockPreScaler
R/W
PulseGeneratorLength[PulseGener
R/W
ator0]
PulseGeneratorLength[PulseGener
R/W
ator1]
CV0
0~4294967295
CV1
0~4294967295
CV2
0~4294967295
CV3
0~4294967295
Values
0:Default
1:UserSet1
LD
2:UserSet2
3:UserSet3
1:UserSet1
SA
2:UserSet2
3:UserSet3
Values
0: Base
1: Medium
CLCFG
2: Full
4: Eighty Bit
0: 85MHz
1: 63.75MHz
CLCF
2: 42.5MHz
3: 31.875MHz
0: Off
SWBR
1: On
0: Off
ADDI
1: On
0:  R
EAS
1:  G
2:  B
Values
PGDEV
1~4096
PGL0
1~1048575
PGL1
1~1048575
CV0?<CR><LF>
-
-
-
Display the counter value.
CV1?<CR><LF>
-
-
-
Display the counter value.
CV2?<CR><LF>
-
-
-
Display the counter value.
CV3?<CR><LF>
-
-
-
Display the counter value.
MIN
MAX
DEFAULT Description
LD=[Param.]<CR><LF>
LD?<CR><LF>
0
3
-
Loads the User Set specified by UserSetSelector to the
device and makes it active.
SA=[Param.]<CR><LF>
SA?<CR><LF>
1
3
-
Save the User Set specified by UserSetSelector to the non-
volatile memory of the device.
MIN
MAX
DEFAULT Description
CLCFG=[Param.]<CR><LF>
CLCFG?<CR><LF>
0
4
0
Set the Camera Link configuration.
CLCF=[Param.]<CR><LF>
CLCF?<CR><LF>
0
3
0
Set Camera Link clock frequency.
SWBR=[Param.]<CR><LF>
SWBR?<CR><LF>
0
1
0
Swap the output of B, R.
ADDI=[Param.]<CR><LF>
ADDI?<CR><LF>
0
1
1
Add additional information during LVAL Low period.
EAS=[Param.]<CR><LF>
EAS?<CR><LF>
0
2
0
Select whether the ExposureActive signal is matched with
the exposure time of R, G, B lines
MIN
MAX
DEFAULT Description
PGDEV=[Param.]<CR><LF>
PGDEV?<CR><LF>
1
4096
1
Set the division value for the prescaler (12 bit) using
PixelClock as the base clock.
PGL0=[Param.]<CR><LF>
PGL0?<CR><LF>
1
1048575
1000000
PulseGeneratorLength in PulseGeneratorClock ticks. This is
the total length of the pulse for every time it is repeated.
PGL1=[Param.]<CR><LF>
PGL1?<CR><LF>
1
1048575
1000000
PulseGeneratorLength in PulseGeneratorClock ticks. This is
the total length of the pulse for every time it is repeated.

Advertisement