PulseGeneratorRepeatCount[Pulse
R/W
Generator3]
PulseGeneratorClearActivation[Pul
R/W
seGenerator0]
PulseGeneratorClearActivation[Pul
R/W
seGenerator1]
PulseGeneratorClearActivation[Pul
R/W
seGenerator2]
PulseGeneratorClearActivation[Pul
R/W
seGenerator3]
PulseGeneratorClearSource[Pulse
R/W
Generator0]
PulseGeneratorClearSource[Pulse
R/W
Generator1]
PulseGeneratorClearSource[Pulse
R/W
Generator2]
PulseGeneratorClearSource[Pulse
R/W
Generator3]
PulseGeneratorClearInverter[Puls
R/W
eGenerator0]
PulseGeneratorClearInverter[Puls
R/W
eGenerator1]
PulseGeneratorClearInverter[Puls
R/W
eGenerator2]
PGRPT3
0~255
0: Off
1: LevelHigh
PGCM0
2: LevelLow
3: RisingEdge
4: FallingEdge
PGCM1
Same as PGCM0
PGCM2
Same as PGCM0
PGCM3
Same as PGCM0
0: Low
1: High
7: ExposureActive
9: LVAL
10: PulseGenerator0
11: PulseGenerator1
12: PulseGenerator2
13: PulseGenerator3
14: UserOutput0
15: UserOutput1
PGIN0
16: UserOutput2
17: UserOutput3
20: Line4: TTL In1
21: Line5: Opt In1
23: Line7 - CC1
24: Line10: TTL In2
26: NAND0 Out
27: NAND1 Out
28: Line13: TTL In3
29: Encoder Trigger
30: Encoder Direction
PGIN1
Same as PGIN0
PGIN2
Same as PGIN0
PGIN3
Same as PGIN0
PGINV0
False/True
PGINV1
False/True
PGINV2
False/True
PGRPT3=[Param.]<CR><LF>
PGRPT3?<CR><LF>
0
255
0
PulseGeneratorRepeatCount. 0 is Infinite
PGCM0=[Param.]<CR><LF>
PGCM0?<CR><LF>
0
4
0
Selects the activation mode of the input to clear the Pulse
Generator.
PGCM1=[Param.]<CR><LF>
PGCM1?<CR><LF>
0
4
0
Selects the activation mode of the input to clear the Pulse
Generator.
PGCM2=[Param.]<CR><LF>
PGCM2?<CR><LF>
0
4
0
Selects the activation mode of the input to clear the Pulse
Generator.
PGCM3=[Param.]<CR><LF>
PGCM3?<CR><LF>
0
4
0
Selects the activation mode of the input to clear the Pulse
Generator.
PGIN0=[Param.]<CR><LF>
PGIN0?<CR><LF>
0
30
0
Selects the source to clear the Pulse Generator.
PGIN1=[Param.]<CR><LF>
PGIN1?<CR><LF>
0
30
0
Selects the source to clear the Pulse Generator.
PGIN2=[Param.]<CR><LF>
PGIN2?<CR><LF>
0
30
0
Selects the source to clear the Pulse Generator.
PGIN3=[Param.]<CR><LF>
PGIN3?<CR><LF>
0
30
0
Selects the source to clear the Pulse Generator.
PGINV0=[Param.]<CR><LF>
PGINV0?<CR><LF>
0
1
0
Controls if the pulse generator clear signal is inverted. False
means "Active High" and True for "Active Low".
PGINV1=[Param.]<CR><LF>
PGINV1?<CR><LF>
0
1
0
Controls if the pulse generator clear signal is inverted. False
means "Active High" and True for "Active Low".
PGINV2=[Param.]<CR><LF>
PGINV2?<CR><LF>
0
1
0
Controls if the pulse generator clear signal is inverted. False
means "Active High" and True for "Active Low".

Advertisement