Flue gas capacity
Mass flow of flue gas
(max-min)
Concentric flue gas discharge pipes
Diameter
Maximum length
Losses for a 45°/90° bend
Hole in wall (diameter)
Concentric flue gas discharge pipes
Diameter
Maximum length
Losses for a 45°/90° bend
Hole in wall (diameter)
Separate flue gas discharge pipes
Diameter
Maximum length
Losses for a 45°/90° bend
Installation B22P-B52P
Diameter
Maximum length of drainage pipe
Emission values at maximum and minimum rate of gas (**)
Maximum
Minimum
(+)
The installation of this product is allowed only in the destination Countries contained in the data plate, regardless of the present translation language.
(*)
Average value of various hot water operating conditions.
(**)
Check performed with concentric pipe Ø 60-100 - length 0.85m - water temperature 80-60°C

MULTIGAS TABLE

DESCRIPTION
Lower Wobbe index (at 15°C-1013 mbar)
Net Calorific Value
Supply nominal pressure (for II2H3B/P)
Supply nominal pressure (for I3B/P)
Supply minimum pressure
Mynute Sinthesi 25 C.S.I.
Main burner: 12 nozzles
Heating maximum gas capacity
DHW maximum gas capacity
Heating minimum gas capacity
DHW minimum gas capacity
Maximum pressure downstream CH valve
Maximum pressure downstream DHW valve
Minimum pressure downstream CH valve
Minimum pressure downstream DHW valve
Mynute Sinthesi 29 C.S.I.
Main burner: 14 nozzles
Heating maximum gas capacity
DHW maximum gas capacity
Heating minimum gas capacity
DHW minimum gas capacity
Maximum pressure downstream CH valve
Maximum pressure downstream DHW valve
Minimum pressure downstream CH valve
Minimum pressure downstream DHW valve
G20
Nm
G31
G20
gr/s
G31
mm
m
m
mm
mm
m
m
mm
mm
m
m
mm
m
CO s.a. lower than
p.p.m.
CO2
%
NOx s.a. lower than
p.p.m.
Flue gas temperature
°C
CO s.a. lower than
p.p.m.
CO2
%
NOx s.a. lower than
p.p.m.
Flue gas temperature
°C
mbar (mm C.A.)
mbar (mm C.A.)
mbar (mm C.A.)
25 C.S.I.
42,168
/h
3
42,147
14,678-14,631
14,678-9,266
14,905-15,076
14,905-9,548
60-100
4,5
1,3/1,6
105
80-125
11
1/1,5
130
80
20 + 20
1/1,5
80
19,5
G20
80
6,8
180
66
80
3,9
130
68
Methane (G20)
MJ/m
S
3
MJ/m
S
3
20 (203,9)
10 (102,0)
Ø mm
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
mbar
mm C.A.
mbar
mm C.A.
mbar
mm C.A.
mbar
mm C.A.
Ø mm
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
mbar
mm C.A.
mbar
mm C.A.
mbar
mm C.A.
mbar
mm C.A.
Mynute Sinthesi C.S.I.
Mynute Sinthesi
29 C.S.I.
42,168
47,081
42,147
45,643
16,371-16,207
16,128-16,331
G31
G20
90
100
7,6
7,1
200
180
64
64
100
60
4,4
3,5
120
110
66
66
Propane (G31)
45,67
34,02
-
1,35
2,64
2,64
1,59
1,00
9,40
95,85
9,40
95,85
3,50
35,69
1,5
15,30
1,35
3,07
3,07
1,59
1,05
9,20
93,81
9,20
93,81
2,70
27,53
1,20
12,24
47,081
45,643
16,371-10,697
16,128-10,779
60-100
4
1,3/1,6
105
80-125
9
1/1,5
130
80
12 + 12
1/1,5
80
12
G31
100
8,2
250
66
190
4,0
180
69
70,69
88
37 (377,3)
37 (377,3)
-
0,76
1,94
1,94
1,16
0,74
35,70
364,04
35,70
364,04
12,80
130,52
4,90
49,97
0,76
2,25
2,25
1,16
0,77
35,50
362,00
35,50
362,00
10,00
101,97
4,50
45,89
13