Installation and Operation Manual
IDRA N DS
Solar | solar storage cylinder
EN
Installation and Operation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IDRA N DS and is the answer not in the manual?

Questions and answers

Summary of Contents for Beretta IDRA N DS

  • Page 1 Installation and Operation Manual IDRA N DS Solar | solar storage cylinder Installation and Operation Manual...
  • Page 3: Table Of Contents

    RANGE MODEL CODE IDRA N DS 1500 20052790 IDRA N DS 2000 20052791 IDRA N DS 2600...
  • Page 4: General

    GENERAL GENERAL SAFETY INFORMATION PRECAUTIONS The operation of any appliance that uses electrical power Check that the product is complete, undamaged and demands that a number of fundamental safety precautions as ordered as soon as you receive it. Report any di- be respected.
  • Page 5: Description Of The Appliance

    First magnesium anode Boiler temperature sensor socket Top coil Auxiliary temperature sensor socket (for models 1500 Il clima di casa Model: IDRA N DS 1500 - 2000) Code: 20052790 Auxiliary temperature sensor socket (for models 2600) Serial Number: K4LH3800001 Cylinder body...
  • Page 6: Technical Specifications

    GENERAL TECHNICAL SPECIFICATIONS IDRA N DS DESCRIPTION 1500 2000 2600 Type of storage cylinder Vitrified Storage cylinder layout Vertical Heat exchanger layout Vertical Diameter of storage cylinder with insulation 1200 1300 1450 Diameter of storage cylinder without insulation 1000 1100...
  • Page 7 GENERAL Pressure drops TOP COIL PRESSURE DROP (mbar) 2000 1500 2600 1000 2000 3000 4000 5000 6000 FLOW RATE (l/h) Pressure drops BOTTOM COIL PRESSURE DROP (mbar) 1000 2000 1500 2600 1000 2000 3000 4000 5000 6000 FLOW RATE (l/h)
  • Page 8: Water Circuit

    Mixer valve storage cylinders are delivered wi- The choice of system components and the method IDRA N DS thout a boiler heating pump. A suitably rated pump of their installation are left up to the heating engineer must be provided and installed separately. Flow rate installing the system.
  • Page 9: Location Of Sensors

    4 bar, fit a pressure reducer. storage cylinders are equipped with de- IDRA N DS dicated sockets for the storage cylinder TEMPERATURE Take care when opening the solar heating circuit’s GAUGE or TEMPERATURE SENSOR.
  • Page 10: Overall Dimensions And Water Fittings

    GENERAL OVERALL DIMENSIONS AND WATER FITTINGS storage cylinders can also be connected to previously installed hot water sources provided heat output IDRA N DS is suitable and care is taken to ensure correct water flow directions. Psc2 Psc1 IDRA N DS...
  • Page 11: Installer 11

    INSTALLER 10 UNPACKING THE PRODUCT MODELS IDRA N DS 2000 storage cylinders come in two separate IDRA N DS packages: MODELS IDRA N DS 1500 - The first contains the painted cylinder, protected by a storage cylinders are delivered in a single IDRA N DS plastic bag and supported on a wooden pallet.
  • Page 12: Handling

    INSTALLER 11 HANDLING MODELS IDRA N DS 2600 storage cylinders come in two separate IDRA N DS packages: - The first contains the painted cylinder, protected by Wear suitable personal protective equipment and use a plastic bag and arranged vertically on a wooden suitable safety devices.
  • Page 13: Installing The Magnesium Anodes

    INSTALLER 12 INSTALLING THE MAGNESIUM MODELS IDRA N DS 2000 To remove the storage cylinder from the pallet, first remove ANODES the insulation then secure lifting cables to the lifting points on the top of the cylinder, and lift with care.
  • Page 14: Fitting The Insulation

    INSTALLER 13 FITTING THE INSULATION MODELS IDRA N DS 2000 to 2600 Once the storage cylinder is correctly positioned inside the room where it is to be installed, proceed to fit the insulation and the accessories to complete the cylinder.
  • Page 15: Place Of Installation

    14 PLACE OF INSTALLATION 15 INSTALLATION IN OLDER SYSTEMS AND SYSTEMS storage cylinders can be installed in any IDRA N DS REQUIRING MODERNISATION room where there is no specific requirement for an electri- cal protection rating higher than IP X0D.
  • Page 16: Technical Assistance Centre

    TECHNICAL ASSISTANCE CENTRE 16 PUTTING INTO SERVICE 17 TEMPORARY SHUTDOWN It is essential to perform the following checks before star- If you are going away for a short period of time like a we- ting up or testing the functioning of the storage cylinder. In ekend or a short holiday, etc., and outdoor temperatures particular, check that: are going to remain above ZERO, proceed as follows.
  • Page 17: Maintenance

    TECHNICAL ASSISTANCE CENTRE 19 MAINTENANCE - Use a 45 mm wrench to unscrew the anode plug (3). Scheduled maintenance is essential for the safety, efficien- cy and long working life of your storage cylinder. Proper maintenance also reduces energy consumption and ensu- res reliability over time.
  • Page 18: Recycling And Disposal

    TECHNICAL ASSISTANCE CENTRE 21 RECYCLING AND DISPOSAL At the end of its useful working life, do not abandon the storage cylinder in the environment, but dispose of it through the proper channels in accordance with applicable legislation. 22 TROUBLESHOOTING SUPPLEMENTARY HEATING CIRCUIT FAULT CAUSE SOLUTION...
  • Page 19: End User

    END USER END USER INSTRUCTIONS Refer to the GENERAL SAFETY INFORMATION and PRECAUTIONS section for safety-related information. 23 START-UP 24 TEMPORARY SHUTDOWN The storage cylinder must be put into service for the first To reduce impact on the environment and save energy, time by personnel from the manufacturer’s Technical Assi- before leaving for the weekend or a short break, etc., pro- stance Centre.
  • Page 20 Commercial Offices: Via Risorgimento, 23 A 23900 - Lecco www.berettaboilers.com Beretta reserves the right to modify the characteristics and specifications given in this publication at any time and without prior notice as part of its policy of continuous product improvement.