EXCLUSIVE GREEN HE C.S.I. - R.S.I.
Forced open installation (B23P-B53P)
Diameter
Max lenght
,OSS FOR A 9o—/45— BEND
Nox
Emission values at maximum and minimum of gas G20 ***
-AXIMUM
-INIMUM
* $(7 VALUES REFER TO '2%%. #.3.). MODELS.

11 - MULTIGAS TABLE

,OWER 7OBBE INDEX (15—#-1o13 MBAR)
Lower heat value
Supply nominal pressure
Supply minimum pressure
EXCLUSIVE GREEN C.S.I. 25 kW
Diaphragm (number of holes)
Diaphragm (diameter of holes)
CH maximum gas capacity
$(7 MAXIMUM GAS CAPACITY
CH minimum gas capacity
$(7 MINIMUM GAS CAPACITY
Numbers of fan revolutions at slow start
Maximum number of fan revolutions
Minimum number of fan revolutions
EXCLUSIVE GREEN C.S.I. 35 kW
Diaphragm (number of holes)
Diaphragm (diameter of holes)
CH maximum gas capacity
$(7 MAXIMUM GAS CAPACITY
CH minimum gas capacity
$(7 MINIMUM GAS CAPACITY
Numbers of fan revolutions at slow start
Maximum number of fan revolutions
Minimum number of fan revolutions
EXCLUSIVE GREEN R.S.I. 25 kW
Diaphragm (number of holes)
Diaphragm (diameter of holes)
CH maximum gas capacity
CH minimum gas capacity
Numbers of fan revolutions at slow start
Maximum number of fan revolutions
Minimum number of fan revolutions
EXCLUSIVE GREEN R.S.I. 35 kW
Diaphragm (number of holes)
Diaphragm (diameter of holes)
CH maximum gas capacity
CH minimum gas capacity
Numbers of fan revolutions at slow start
Maximum number of fan revolutions
Minimum number of fan revolutions
10
mm
m
m
#/ S.A. LOWER THAN
#/
2
./X S.A. LOWER THAN
T fumes
#/ S.A. LOWER THAN
#/
2
./X S.A. LOWER THAN
T fumes
** !VERAGE VALUE AMONG VARIOUS SANITARY RUNNING CONDITIONS.
MJ/m
3
S
MJ/m
3
S (MJ/kgS)
mbar (mm H
mbar (mm H
n.
mm
Sm
3
/h
kg/h
Sm
3
/h
kg/h
3
Sm
/h
kg/h
Sm
3
/h
kg/h
revs/min
revs/min
revs/min
n.
mm
Sm
3
/h
kg/h
3
Sm
/h
kg/h
Sm
3
/h
kg/h
Sm
3
/h
kg/h
revs/min
revs/min
revs/min
n.
mm
3
Sm
/h
kg/h
Sm
3
/h
kg/h
revs/min
revs/min
revs/min
n.
mm
Sm
3
/h
kg/h
3
Sm
/h
kg/h
revs/min
revs/min
revs/min
C.S.I. 35 kW
C.S.I. 25 kW
80
80
50
60
1,5/1
1,5/1
5
5
180
180
9,0
9,0
45
35
76
74
5,0
10
9,5
9,5
10
15
59
62
*** 4ESTED WITH Œ6o-1oo CONCENTRIC - LENGHT o,85M - WATER TEMPERATURE 8o-6o—#.
G20
45,67
34,02 (-)
/)
20 (203,9)
2
/)
10 (102.0)
2
2
3,65
2,64
-
2,64
-
0,26
-
0,26
-
3.700
6.000
1.200
2
3,80
3,66
-
3,66
-
0,37
-
0,37
-
3.300
6.000
1.200
2
3,65
2,64
-
0,26
-
3.700
6.000
1.200
2
3,80
3,66
-
0,37
-
3.300
6.000
1.200
R.S.I. 25 kW
R.S.I. 35 kW
80
80
60
50
1,5/1
1,5/1
5
5
180
180
9,0
9,0
45
35
76
74
5,0
10
9,5
9,5
10
15
59
62
G31
70,69
88 (46,34)
37 (377)
-
2
2,95
-
1,94
-
1,94
-
0,35
-
0,35
3.700
6.000
1.900
2
3,05
-
2,69
-
2,69
-
0,27
-
0,27
3.300
5.900
1.900
2
2,95
-
1,94
-
0,19
3.700
6.000
1.900
2
3,05
-
2,69
-
0,27
3.300
5.900
1.900