11 - MULTIGAS TABLE

Lower Wobbe index (15°C-1013 mbar)
Lower heat value
Supply nominal pressure
Supply minimum pressure
EXCLUSIVE GREEN E 25 C.S.I.
Diaphragm (number of holes)
Diaphragm (diameter of holes)
CH maximum gas capacity
DHW maximum gas capacity
CH minimum gas capacity
DHW minimum gas capacity
Numbers of fan revolutions at slow start
Maximum number of CH fan rotations
Maximum number of DHW fan rotations
Minimum number of CH fan rotations
Minimum number of DHW fan rotations
EXCLUSIVE GREEN E 30 C.S.I.
Diaphragm (number of holes)
Diaphragm (diameter of holes)
CH maximum gas capacity
DHW maximum gas capacity
CH minimum gas capacity
DHW minimum gas capacity
Numbers of fan revolutions at slow start
Maximum number of CH fan rotations
Maximum number of DHW fan rotations
Minimum number of CH fan rotations
Minimum number of DHW fan rotations
EXCLUSIVE GREEN E 35 C.S.I.
Diaphragm (number of holes)
Diaphragm (diameter of holes)
CH maximum gas capacity
DHW maximum gas capacity
CH minimum gas capacity
DHW minimum gas capacity
Numbers of fan revolutions at slow start
Maximum number of CH fan rotations
Maximum number of DHW fan rotations
Minimum number of CH fan rotations
Minimum number of DHW fan rotations
EXCLUSIVE GREEN E 25 R.S.I.
Diaphragm (number of holes)
Diaphragm (diameter of holes)
CH maximum gas capacity
DHW maximum gas capacity (*)
CH minimum gas capacity
DHW minimum gas capacity (*)
Numbers of fan revolutions at slow start
Maximum number of CH fan rotations
Maximum number of DHW fan rotations (*)
Minimum number of CH fan rotations
Minimum number of DHW fan rotations (*)
EXCLUSIVE GREEN E 35 R.S.I.
Diaphragm (number of holes)
Diaphragm (diameter of holes)
CH maximum gas capacity
DHW maximum gas capacity (*)
CH minimum gas capacity
DHW minimum gas capacity (*)
Numbers of fan revolutions at slow start
Maximum number of CH fan rotations
Maximum number of DHW fan rotations (*)
Minimum number of CH fan rotations
Minimum number of DHW fan rotations (*)
(*) DHW functions refer only if a water thank is connected
Methane gas (G20)
MJ/m
S
3
MJ/m
S
3
mbar (mm H
O)
2
mbar (mm H
O)
2
number
mm
1x4,70 flap + 1x4,20 free
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
revs/min
revs/min
revs/min
revs/min
revs/min
number
mm
1x4,30 flap + 1x4,20 free
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
revs/min
revs/min
revs/min
revs/min
revs/min
number
mm
1x5,1 flap + 1x4,7 free
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
revs/min
revs/min
revs/min
revs/min
revs/min
number
mm
1x4,70 flap + 1x4,20 free
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
revs/min
revs/min
revs/min
revs/min
revs/min
number
mm
1x5,1 flap + 1x4,7 free
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
revs/min
revs/min
revs/min
revs/min
revs/min
Propane (G31)
45,67
34,02
88 (46,34)
20 (203,9)
37 (377,3)
10 (102,0)
2
1x3,40 flap + 1x3,25 free
2,12
2,64
0,30
0,30
3.700
4.500
5.600
1.200
1.200
2
1x3,40 flap + 1x3,25 free
2,64
3,17
0,34
0,34
3.700
5.100
5.700
1.200
1.200
2
3,17
3,66
0,38
0,38
3.300
5.300
6.000
1.200
1.200
2
1x3,40 flap + 1x3,25 free
2,12
2,64
0,30
0,30
3.700
4.500
5.600
1.200
1.200
2
3,17
3,66
0,38
0,38
3.300
5.300
6.000
1.200
1.200
ENGLISH
70,69
-
2
1,55
1,94
0,31
0,31
3.700
4.500
5.600
1.500
1.500
2
1,94
2,33
0,35
0,35
3.700
4.900
5.600
1.500
1.500
2
2x3,55
2,33
2,69
0,39
0,39
3.300
5.400
5.900
1.500
1.500
2
1,55
1,94
0,31
0,31
3.700
4.500
5.600
1.500
1.500
2
2x3,55
2,33
2,69
0,39
0,39
3.300
5.400
5.900
1.500
1.500
13