5.3.2

Adjust "Sauna with humidity" mode (only FCUx200 and FCUx400)

The control unit is turned on.
In the mode "Sauna with humidity" additionally the humidity can be adjusted.
1.
Fig. 5: "Sauna with humidity" view (example)
Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09
PLEASE NOTE!
Cabin damage for e.g. mould growth due to premature stopping of
the drying function!
After completion of the "sauna with humidity" mode (min. 10 minutes
operation), the cabin is automatically dried for a certain time at a certain
temperature. This drying function is used to avoid cabin damage such
as mould growth.
Therefore:
– Do not stop the drying function prematurely.
– The drying function may only be stopped if the cabin is subsequently
operated in "Sauna" mode.
– If the drying function is stopped accidentally, a message appears on
the display. Start the drying function again by following the instruc-
tions on the display.
NOTE!
The adjustable set point humidity and set point temperature are limited
for safety reasons (fire hazard). With a higher set point temperature, the
allowable set point humidity decreases. For e.g. at a set point tempera-
ture of 55 ° C, the maximum adjustable set point humidity is 46%. If the
set point temperature increases, the maximum adjustable set point hu-
midity decreases. This dependence between temperature and humidity
is not linear.
Press the
key until the symbol
chapter 5.3.3.



(adjust humidity) lights up. → See page 22,

