Maximum allowed heating time

After starting a mode, the remaining heating time is displayed in place of the full heating
time. The heating time can be changed only in standby mode.
The EN 60335-2-53 "Specific requirements for sauna heating devices" allows the follow-
ing maximum heating times:
Max. heating time
more than 12 hours
max. 12 hours
max. 6 hours
Table: 7 Maximum heating time
The control devices are delivered with a maximum adjustable heating time of 6 hours. If
you need heating times exceeding 6 hours, please contact the installer or the dealer of
your sauna system.
Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09
The timer may be enabled or disabled depending on the setting. In the series
FCU2x00 and FCU3x00, weekly timer is not available.
The "Sauna" (Fig. 4), "Sauna with humidity" (Fig. 5) or "Infrared" (Fig. 6) view is
displayed.
Press the
key till the symbol
Press the
key.
Following view is displayed:



Press the
key. Last digit flashes.
Adjust the desired value:
Press the
key: Reduce value.
Press the
key: Increase value.
Note!
After the digit "9" or "0", the higher digit of the temperature value is changed. That
is "90" is displayed after "89".
You can also select the higher digit using the
Press the
key. The adjusted value is accepted
(adjust temperature) lights up.


key or
Description
Public cabins which are supervised by trained
personnel.
Hotels, apartment blocks, etc.
All other cabins / private households
Operation
key and then change.