If The Sauna Control Device Is Installed In The Technical Room - Fasel Elektronik FCU2000 Series Installation Instructions Manual

Sauna control
Hide thumbs Also See for FCU2000 Series:
Table of Contents

Advertisement

2.3

If the sauna control device is installed in the technical room

The control device can be installed directly on the outer side of the cabin or at another
If the sauna
location, however not within the cabin. If the installation is not done directly on the outer
control device
wall of the cabin then the following points should be noted:
is not directly
installed on the
Lay the signal cables separately from the power line.
outer wall of the
Do not lay the signal cables parallel to the power line.
cabin
Install a distribution box for the signal lines and another one for the power lines as per
Note EN 60335-2-53 for remote start
Figure 1: Cabling while installing the sauna control device not directly on the outer wall of the cabin
Installation instructions Sauna control Series FCU2x00/FCU3x00/FCU4x00 / Version V 2.18
NOTE!
FASEL additionally offers a extension power unit for loads of 9 kW, 18
kW and 24 kW.
Figure 1
Technical Data
11

Advertisement

Table of Contents
loading

Table of Contents