Hot melt application head EP 30
14

Regular Maintenance

Unit part
Control modules
Nozzle
Power cable
Air hoses

Replacing Control Module

Cleaning Nozzle

P/N 397191B
Activity
Check detection holes
Replace
Cleaning
Replace
Inspect for damage
Inspect for damage
WARNING: Hot! Risk of burns. Wear heat-protective gloves.
Nordson recommends keeping control modules on hand to avoid
interruptions in production (Refer to Spare Parts List).
1. Relieve pressure.
2. Release air connection and electrical connection.
3. Release screws and extract control module from warm application head.
4. Insert new control module; tighten screws crosswise.
5. Re-connect air and electrical connection.
WARNING: Hot! Risk of burns. Wear heat-protective gloves.
Nordson recommends keeping nozzles on hand to avoid interruptions in
production (Refer to Spare Parts List).
1. Unscrew nozzle from application head.
2. Clean nozzle with a cleaning agent or a soft cloth.
3. Inspect nozzle for damage, replace if necessary
4. Screw clean nozzle onto the application head again.
EP 30
Interval
Daily
When damaged
Regularly, or when the
application pattern
deteriorates
When damaged
Every time the application
head is serviced
Every time the application
head is serviced
Refer to
Page 13
Page 14
Page 14
E 2005 Nordson Corporation