This screen shows the unit used <hrs> (or <x1000 hrs>) and the value <1191>. In the example shown, the
compressor has run 1191 hours since the previous service.
Resetting the service timer
After servicing, see section
• Scroll to register screen <d.6> and press Enter button (13).
• The reading (e.g. 4000) will appear.
• Press Enter button (13) and - if a password is set - enter the password.
The icon will flash (indicating that resetting is possible).
• Press Enter button (13) to reset the timer to <0.000> or press the Escape button (14) to cancel the operation.

3.16 Selection between local, remote or LAN control

Starting from the Main screen:
• Press Scroll button (12) until <P.01> is shown and then press Enter button (13). The actually used control
mode is shown: <LOC> for local control, <rE> for remote control or <LAn> for LAN control.
• Press Enter button (13) and if necessary enter the password. The actually used control mode is blinking.
Use Scroll button (12) to change the control mode.
• Press Enter button (13) to program the new starting mode or press Escape button (14) to cancel.

3.17 Calling up/modifying CAN address control

Calling up
Starting from the main screen,
Press the Scroll button (12) until <P.02> is shown and then press Enter button (13).
2920 7090 51
Service
warning, the timer has to be reset: