9

Adjustments and servicing procedures

9.1

Drive motor

General
Keep the outside of the electric motor clean for efficient cooling. If necessary, remove dust with a brush and/
or compressed air jet.
Bearing maintenance
The motor bearings are greased for life.
9.2

Air filter

Location of air filter
Recommendations
1. Never remove the element while the compressor is running.
2. For minimum downtime, replace the dirty element by a new one.
3. Discard the element when damaged.
Procedure
1. Stop the compressor. Switch off the voltage.
2. Remove the cover of air filter (AF) by turning it anti-clockwise. Remove the filter element. If necessary,
clean the cover.
3. Fit the new element and the cover.
4. Reset the air filter service warning.