This screen shows the unit used <hrs> (or <x1000 hrs>) and the value <1191>. In the example shown, the
compressor has run 1191 hours since the previous service.
Resetting the service timer
After servicing, see section
• Scroll to register screen <d.6> and press Enter button (13).
• The reading (e.g. 4000) will appear.
• Press Enter button (13) and - if a password is set - enter the password.
The icon will flash (indicating that resetting is possible).
• Press Enter button (13) to reset the timer to <0.000> or press the Escape button (14) to cancel the operation.

3.16 Selection between local, remote or LAN control

Starting from the Main screen, press Scroll button (12) until <P. 1> is shown and then press Enter button (13).
The actually selected control mode is shown: <LOC> for local control, <rE> for remote control or <LAn>
for LAN control.
To change: press Enter button (13) and - if necessary - enter the password (see section
protection). The actually selected control mode is blinking. Use Scroll button (12) to change the control mode.
Press Enter button (13) to program the new control mode or press Escape button (14) to cancel.

3.17 Calling up/modifying CAN address control

Calling up
Starting from the main screen, press the Scroll button (12) until <P. 2> is shown and then press Enter button
(13).
2920 7109 60
Service
warning, the timer has to be reset:
Activating password
43