3.31 Test screens

Display test
Starting from the Main screen:
• Press Scroll buttons (12) until <t.01> is shown and then press Enter button (13).
Safety valve test
In the test screen <t.02> a safety valve test is provided. The safety valves can only be tested after entering a
code. Consult Atlas Copco if the safety valves are to be tested.
Production test
Test screen <t.03> is only intended for production test. If the Main screen shows following screen, the
controller is in production test mode:
How to solve?
Use the Scroll buttons (12) and scroll to menu <t.03>.
The screen shows:
Press the Enter button (13): the text starts blinking. Press enter again and the menu disappears.
2920 7090 51