LIMIT SWITCH ADJUSTMENT

• Isolate the power supply to the system.
• Back off the screw retaining the front adapter 13a and then slide it out 13b .
• Slide out the aluminium micro-switch cover profile 13c .
• Slacken the screw locking the limit switch, move the limit switch into the required position and tighten the limit
switch lock screw 13d .

RELEASE DEVICE

MANUAL OPERATION

If the gate had to be operated manually because of a power failure or malfunction of the automation,
move the protection tab 12a , insert the specific key supplied into the lock, turn the key clockwise
or anticlockwise by 90° 12b and pull the release lever upwards 12c .
If the lever is completely pulled, the operator remains free without having to hold the lever with the
[
]
hand 12d .
Manually perform the door opening or closing operation.
To prevent the door moving because of wind or if it is not balanced, it is advisable, after having performed the
emergency manual manoeuvre, to re-lock the operator by lowering the lever until it is fully inserted in its seat,
turn the key clockwise or anticlockwise by 90° as shown in 12b , then remove the key (the key can only be
removed when it is in a certain position), then slightly move the door until it locks.
ELECTRIC LOCK ASSEMBLY
If an electric lock had to be fitted, refer to 11a 11b :
À
Electric lock
Á
Electric lock securing plate
Â
Mouth
Ã
Mouth locator
Ä
Latch
Å
Through cylinder (optional)
Æ
Gate
[
]
[
]
[
]
[
[
]
[
]
[
[
]
] [
]