Operator Installation - GiBiDi BL233 Instructions For Installation Manual

Electromechanical linear operator
Table of Contents

Advertisement

Available languages

Available languages

BL230-BL233

OPERATOR INSTALLATION

• Verify and mark the most suitable securing centre for the front bracket of the operator 2 .
• Use a level to mark the point on the pillar for securing the rear bracket 2 .
• Identify a securing centre for the rear bracket in relation to dimensions A-B and E 3 .
WARNING: if there are large pillars or walls, a niche should be prepared to ensure that dimensions
A, B and E are observed 4 .
Securing the rear bracket:
- welding for metal pillars; (check the thickness of the column and if less than 5 mm fit a support plate of
suitable dimensions so that the welds are made on the edge of the column; see 5 .
- if the pillar is in cement, the bracket can be fixed with plugs or masonry by means of an appropriate
[ ]
extension 6 .
• Take the operator and move the lead screw fully forwards as far as the block, then back of by 5-10 mm; this
operation can also be performed manually by releasing the operator (see release device).
• Fix the front bracket onto the operator 7 .
• Place the door in the closed position in relation to the mechanical stops and secure it with a clamp.
• Fit the operator on the rear bracket using the pin supplied 8 .
• Place the front bracket at the point previously marked at stage 1 and use a level to check the flatness of the
operator; mark the point for exact securing of the front bracket 2 3 .
• Remove the operator from the rear bracket.
• Remove the front bracket of the operator.
• Fix the front bracket at the point marked.
Securing the front bracket:
- welding for metal gates; (check the thickness of the tubular element where the bracket is to be welded; if less
than 5 mm, fit a support plate of suitable dimensions so that the welds are made on the edge of the tubular
[ ]
unit 9 .
- for gates in non-metal materials, a 5 mm shim plate is required. With n°4 holes, weld the bracket to the centre
of the plate and secure everything with 8 mm through screws 10 .
• Release the operator (see release device).
• Fit the operator on the brackets.
• Open and close the door manually, performing complete opening and closing travel. Movement must be
smooth and the lead screw, for both opening and closing, should not reach the mechanical block. If this is not
the case, review brackets positioning.
• Make the electrical connections between the operator and the control unit with reference to the diagram 1c ,
using 1,5 mm² cores.
It is advisable to leave a free cable length of at least 40/50mm. To facilitate electrical connections, the
operator can be temporarily turned upside-down.
[ ]
[ ]
[ ]
[ ]
[ ]
[ ] [ ]
[
]