WARNINGS FOR THE USER

In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical
Service.
Periodically check functioning of the safety devices.
Any repairs must be carried out by specialised personnel using original and certified materials.
The product may not be used by children or persons with reduced physical, sensorial or mental capacities, or
lacking experience and knowledge, unless appropriately instructed.
Do not access the circuit board for adjustments and/or maintenance.
CAUTION: IMPORTANT SAFETY INSTRUCTIONS
It is important to follow these instructions in order to safeguard persons.
Keep this instruction booklet.

ELECTRICAL EQUIPMENT

Set up the electric system as shown 1a 1b referring to the electric system regulations and other national
regulations in force. Keep the mains power connections clearly separated from the service connections
(photocells, sensitive frames, control devices, etc.).
The main components are:
À
Antenna: screened coaxial cable.
Á
Electronic equipment housing.
Â
Electric lock: cable with 2 cores - 1 mm² (2x1).
Ã
Key selector; cable with 3 cores - 0.5 mm² (3x0.5).
220 - 230 Vac Operators 1c :
Ä
Power supply: cable w/ 4 cores - 1,5 mm² (4x1,5):
grey = COMMON; brown = POWER SUPPLY; black = POWER SUPPLY; yellow/green = EARTH
Å
Omnipolar magnetothermal switch with minimum contact opening of 3 mm.
220-230VAC/50-60 Hz power line to the device: cable with 3 cores - 1.5 mm² (3x1.5) (adhere to the
regulations in force).
Æ
220V Warning system - flashing light: cable with 2 cores - 1.5 mm² (2x1,5).
Ç
Shunt boxes.
È
Photocell transmitter: cable with 2 cores - 0.5 mm² (2x0.5).
É
Photocell receiver: cable with 4 cores - 0.5 mm² (4x0.5).
CAUTION:
It is important that an omnipolar magnetothermal switch, with a minimum contact opening of
3 mm, is fitted upstream of the control unit.
[
] [
]
[
]