G
E
T
Ensure the plugs and jacks meet the dimension, tolerance and metallic plating requirements of
47 C.F.R. Part 68, SubPart F .
For proper operation there must be no other telephone equipment connected between the
control panel and the telephone company facilities .
Do not connect the alarm panel communicator to telephone lines intended for use with a FAX
machine. These lines may incorporate a voice filter which disconnects the line if anything
other than FAX signals are detected, resulting in incomplete transmissions .
2.3
Keybus Operation and Wiring
The Keybus is used by the panel to communicate with all modules connected and by the modules to talk to
the panel. The RED and BLK terminals are used to provide power while YEL and GRN are clock and data.
The 4 Keybus terminals of the panel must be connected to the 4 Keybus terminals or wires of
all modules.
The following conditions apply:
• Keybus should be run in minimum 22 gauge quad (0.5mm), two pair twist preferred
• the modules can be home run to the panel, connected in series or can be T-tapped
• any module can be connected anywhere along the Keybus, you do not need a separate Keybus wire run
for keypads, zone expanders etc.
• no module can be more than 1,000'/330m (in wire length) from the panel
• shielded wire is not necessary unless wires are run in an area that may present excessive RF noise or
interference
Example of Keybus Wiring
150'
150'
150'
150'
PANEL
PANEL
500'
500'
NOTE: Module (A) is wired correctly as it is within 1,000'/330m of the panel, in wire distance.
Module (B) is wired correctly as it is within 1,000'/330m of the panel, in wire distance
Module (C) is NOT wired correctly as it is further than 1,000'/330m from the panel, in wire distance.
2.4
Current Ratings - Modules and Accessories
In order for the PC5010 system to operate properly, the power output capabilities of the main control and
expansion devices must not be exceeded. Use the data presented below to ensure that no part of the
system is overloaded and cannot function properly.
System Outputs (all 12 V
• PC5010
VAUX: 500 mA. Includes one keypad. Subtract for each additional keypad, expansion module and
accessory connected to VAUX or Keybus.
BELL: 700 mA. Continuous Rating.
3.0 A. Short Term. Available only with stand-by battery connected.
• PC5204
VAUX: 1.0 A. Continuous Rating. Subtract for each device connected.
3.0 A. Short Term. Available only with stand-by battery connected.
• PC5208
VAUX: 250 mA. Subtract for each device connected. Subtract the total load on this terminal from the
PC5010 VAUX/Keybus output.
• PC5108
VAUX: 100 mA. Subtract for each device connected. Subtract the total load on this terminal from the
PC5010 VAUX/Keybus output.
PC5010 Device Ratings (@ 12 V
• LCD5500 Keypad: 50 mA
• PC5532 Keypad: 45 mA
• PC5516 Keypad: 45 mA
• PC5508 Keypad: 45 mA
• PC5108 Zone Module: 35 mA
• PC5204 Output Module: 20 mA
• PC5208 Output Module: 50 mA
T
I
N
G
B
B
C
C
500'
500'
A
A
)
DC
)
DC
S
T
• PC5132 Wireless Module: 125 mA
• Escort5580 Module: 150 mA
• PC5928 Audio Interface Module: 65 mA
• PC5921 Intercom Audio Station: 20 mA
• PC5921 EXT Door Box Audio Station: 20 mA
• PC5921 EXT/R Door Box Audio Station: 35 mA
• PC5400 Printer Module: 62 mA