Download Print this page

DSC Power832 Installation Manual page 33

Hide thumbs Also See for Power832:

Advertisement

P
R
O
G
[16] LINKS1000 Support (PGM1 Only)
The PGM output will be used as a data wire to communicate phone number information for the LINKS1000
cellular unit.
[17] Away Armed
The PGM will activate when the system is armed with the Stay/Away zones activated.
[18] Stay Armed
The PGM will activate when the system is armed with the Stay/Away zones bypassed.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Main Board PGM Outputs ............................. Section [009]
PC5208 PGM Output Options ....................... Section [010]
PC5204 PGM Output Options ....................... Section [011]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.10.2
PGM Output Attributes
Each Programmable Output also requires the PGM Attributes to be programmed before they will operate
correctly. Attributes available are as follows:
Option [1] - ON Partition 1 Controls Event
OFF Partition 1 Does Not
Option [2] - ON Partition 2 Controls Event
OFF Partition 2 Does Not
Option [3] - ON Output Activates on Event
OFF Output Deactivates on Event
The Attribute Options for Option [09] System Trouble and [10] Latched System Event are
different. Refer to these options for more information.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
PGM1 (Main Board) Output Attributes .......... Section [141]
PGM2 (Main Board) Output Attributes .......... Section [142]
PC5208 PGM Output Attributes .................... Section [143] to [150]
PC5204 PGM Output Attributes ..................... Section [151] to [154]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.11
Telephone Line Monitor (TLM)
The panel will supervise the presence of the phone line and indicate a trouble condition if disconnected. If
TLM Enabled is selected the panel will wait the TLM Trouble Delay time before indicating the trouble so
that a momentary interruption of the phone line will not cause a trouble condition.
The TLM Trouble Only or Audible When Armed option will allow you to select if the panel will indicate a
trouble condition at the keypad or indicate a trouble at the keypad when disarmed and activate the alarm
output when armed.
When the trouble condition is restored the panel can send a TLM Restoral Reporting Code. Any events
that occurred while the phone line was down will also be communicated.
If the LINKS1000 cellular communicator is being used the panel can be programmed to report a TLM
Trouble Reporting Code.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
TLM Enable/Disable ...................................... Section [015], Option [7]
TLM Trouble Only or Audible When Armed ... Section [015], Option [8]
TLM Trouble Delay ......................................... Section [370]
TLM Trouble Reporting Code ........................ Section [349]
TLM Restoral Reporting Code ........................ Section [350]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.12
Siren Supervision
The panel supervises the Bell output. If an open condition is detected or the fuse is blown the panel will
immediately indicate a trouble condition and beep the keypad twice every ten seconds to alert the owner
of the problem. The panel can send a Bell Circuit Trouble Reporting Code immediately. Once the
problem is corrected the panel can send a Bell Circuit Trouble Restoral Reporting Code.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Bell Circuit Trouble Reporting Code .............. Section [349]
Bell Circuit Trouble Restoral Reporting Code Section [350]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
R
A
M
D
E
S
C
R
I
33
P
T
I
O
N
S

Advertisement

loading

This manual is also suitable for:

Pc5010