[05] Partition/System Armed Status
The PGM output will activate when the Partition or System is armed and deactivate when disarmed.
[06] Ready Output
The PGM output will activate when the Partition or System is ready to arm. The output will deactivate when
the system is not secure or upon arming.
[07] Keypad Buzzer Follow
The PGM will activate when any of the following events occur and will remain active for as long as the
keypad buzzer is active:
• Door Chime
• Auto-Arm Prealert
[08] Courtesy Pulse
Upon arming the PGM output will activate for the duration of the exit delay plus two minutes. Upon entry
the PGM output will activate for the duration of the entry delay plus two minutes. Only one courtesy pulse
output may be programmed on a system.
[09] System Trouble
The PGM output will activate when any of the selected trouble conditions are present. It will deactivate
when all the selected trouble conditions are cleared.
The normal PGM attributes, programmed in Sections [141] to [154] is replaced with the following list for
any output selected as System Trouble:
Light [1] Service Required (battery, bell, general trouble, general tamper, general supervisory)
Light [2] AC Failure
Light [3] Telephone Line Trouble
Light [4] Failure to Communicate
Light [5] Fire Trouble / Zone Fault
Light [6] Zone Tamper
Light [7] Zone Low Battery
Light [8] Loss of Clock
[10] Latched System Event
The PGM output will activate when any of the selected events occur. It will deactivate when an access
code is entered.
The normal PGM attributes, programmed in Sections [141] to [154] is replaced with the following list for
any output selected as Latched System Event:
Light [1] Burglary ......... Delay, Instant, Interior, Stay/Away and 24 Hour Burglary Zones
Light [2] Fire ................ Fire Keys, Fire Zone and Two Wire Smoke Zone (PGM Output)
Light [3] Panic ............. Panic Keys and Panic Zone
Light [4] Medical ......... Auxiliary Keys, Medical and Emergency Zones
Light [5] Supervisory ... Supervisory, Freezer and Water Zones
Light [6] Priority ........... Gas, Heat, Sprinkler and 24 Hour Latching Zones
Light [7] Holdup .......... Holdup Zones and Duress Alarms
Light [8] Not Used
[11] System Tamper
The PGM Output will activate when any Tamper condition is present and will deactivate when all Tamper
conditions are cleared.
[12] TLM and Alarm
The PGM Output will activate when a telephone line fault condition is present AND an alarm occurs. The
PGM Output will remain active until an access code is entered. The output will activate for both audible
and silent alarms if a TLM trouble is present.
This output will activate for all audible and silent alarms except Duress.
[13] Kissoff
The PGM Output will activate for two seconds after the panel receives the kissoff from the central station.
[14] Ground Start (Shall not be used on UL Listed systems)
The PGM Output will activate for two seconds before the panel attempts to dial to obtain dial tone on
Ground Start telephone equipment. Two 2-second pauses should be inserted at the beginning of the
phone number when using this option.
[15] For future use
A
M
D
E
• Entry Delay
• 24 Hour Supervisory Buzzer Zone
32
S
C
R
I
P
• Audible Exit Delay
T
I
O
N
S