DSC Power832 Installation Manual page 6

Hide thumbs Also See for Power832:

Advertisement

G
E
T
T
Do not connect the battery until all other wiring is complete . . . . .
Connect the RED battery lead to the positive of the battery, the BLACK battery lead to the negative.
Auxiliary Power Terminals - AUX+ and GND
These terminals provide up to 500 mA of additional current at 12 V
residential applications) for devices requiring power. Connect the positive side of any device requiring
power to the AUX+ terminal, the negative side to GND. The AUX output is protected; if too much current is
drawn from these terminals (wiring short) the panel will temporarily shut off the output, until the problem is
corrected.
Bell Output Terminals - BELL+ and BELL-
These terminals provide up to 3 Amps of current at 12 V
applications) (with stand-by battery; 700 mA continuous) for powering bells, sirens, strobes or other
warning type equipment. Connect the positive side of any alarm warning device to BELL+, the negative
side to BELL–. The BELL output is protected; if too much current is drawn from these terminals (wiring
short) the BELL fuse will open.
The Bell output is supervised. If no alarm warning device is being used connect a 1000 ohm resistor
across BELL+ and BELL– to prevent the panel from displaying a trouble condition (See
Commands, [
][2]").
Keybus Terminals - RED, BLK, YEL, GRN
The Keybus is used by the panel to communicate with modules and by modules to communicate with the
panel. Each module has four Keybus terminals that must be connected to the four Keybus terminals on the
panel. For more information, see
Programmable Outputs - PGM1 and PGM2
Each PGM output is an open collector switch to ground. That is, when the PGM output is activated by the
panel the terminal will switch to ground.
PGM1 can sink up to 50 mA of current to activate LEDs or a small buzzer. Connect the positive side of the
LED or buzzer to AUX+, the negative side to PGM1. If more than 50 mA of current is required a relay must
be used. Refer to the following diagram:
PGM2 operates similar to PGM1.
Zone Input Terminals - Z1 to Z8
Each detection device must be connected to a zone on the control. It is suggested that each zone have
one detection device however it is possible to wire multiple detection devices to the same zone.
For zone wiring specifics, see
Telephone Connection Terminals - TIP, RING, T-1, R-1
If a telephone line is required for central station communication or downloading connect an RJ-31X jack in
the following manner:
• RING - Red Wire ........ Incoming line from
• TIP - Green Wire
I
N
G
Section 2.3 "Keybus Operation and
Section 2.9 "Zone Wiring"
telephone company
6
S
T
A
(rated 11.6 - 12.6 V
DC
(rated 11.6 - 12.6 V
DC
Wiring".
.
• R-1 - Grey Wire .......... Outgoing line to
• T-1 - Brown Wire
house telephone(s)
R
T
E
D
for UL
DC
for UL residential
DC
Section 3.4 "[ ]