DSC  Power832 PC5O15 Instruction Manual

DSC Power832 PC5O15 Instruction Manual

Tyco security system instruction manual
Hide thumbs Also See for DSC Power832 PC5O15:

Advertisement

WARNING
This manual contains information on limitations regarding product use and
function and information on the limitations as to liability of the manufacturer.
The entire manual should be carefully read.
Instruction
Manual
PC5O15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DSC Power832 PC5O15 and is the answer not in the manual?

Questions and answers

Summary of Contents for DSC DSC Power832 PC5O15

  • Page 1 WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. Instruction Manual PC5O15...
  • Page 2: Note To Installers

    WARNING Please Read Carefully Note to Installers This warning contains vital information. As the only individual in contact with system users, it is your responsibility to bring each item in this warning to the attention of the users of this system. System Failures This system has been carefully designed to be as effective as possible.
  • Page 3: About Your Security System

    About Your Security System Your DSC Power832 Security System has been designed to provide you with the greatest possible flexibility and convenience. Read this manual carefully and have your installer instruct you on your system's operation and on which features have been implemented in your system. All users of this system should be equally instructed in its use.
  • Page 4: System Information

    System Information Fill out the following information for future reference and store this manual in a safe place. Access Codes Your Master Code is: __________________________________________ Additional Access Codes: 01 __________________ 09 ____________________ 02 __________________ 10 ____________________ 03 __________________ 11 ____________________ 04 __________________ 12 ____________________ 05 __________________...
  • Page 5 ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ [F] FIRE __________________________________________ [A] AUXILIARY ____________________________________ [P] PANIC ________________________________________ The Exit Delay Time is ________ seconds. The Entry Delay Time is ______ seconds. For Service Central Station Information: Account #: ___________________________________...
  • Page 6: Access Codes

    Access Codes Access codes are used to arm and disarm the system. There are 37 access codes available: 1 master code, 32 regular access codes, 2 duress codes and 2 partition master codes. Ask your installer for more information on using the duress and partition master codes. Only the Master Code can be used to program additional security codes and to change other system features as well as to arm and disarm the security system.
  • Page 7: Alternate Arming Methods

    Alternate Arming Methods Away Arming Arming the system in the Away mode will have all interior zones and perimeter zones active. If motion is detected in the interior zones, or if one of the perimeter zones is violated, the alarm sequence will begin.
  • Page 8: Disarming The System

    Disarming the System Disarming from an LED or LCD5501Z Keypad: Enter the premises through a designated Exit/Entry door; entering by any other door will sound an immediate alarm. As soon as the Exit/Entry door is opened, the keypad will beep to indicate that the system should be disarmed.
  • Page 9: If An Alarm Sounds

    If An Alarm Sounds Fire Alarm If your system has been installed with fire detectors and the alarm sounds in a pulsing mode, follow your emergency evacuation plan immediately (see “Fire Escape Planning” on page 15). Intrusion Alarm If an intrusion alarm sounds, indicated by a continuous bell or siren, the alarm may be silenced by entering your access code.
  • Page 10 PC5508(Z) LED Keypad PC5516(Z) LED Keypad Display Lights Ready Light (All keypads) If the Ready light is ON, the system is ready for arming. If the Ready light is OFF, check to see that all doors and windows are closed and that all movement is stopped in areas covered by motion detectors.
  • Page 11 PC5532(Z) LED Keypad Memory Light (LED keypads only) Upon disarming, if an alarm has occurred while the system was armed, the Memory light will turn ON (See “Disarming the System” on page 6). Bypass Light (LED keypads only) If the Bypass light is ON, ensure that zones are intentionally bypassed before arming the system (See “Zone Bypassing”...
  • Page 12 LCD5500(Z) Keypad LCD5501Z Keypad LCD5500(Z) Keypad: The Liquid Crystal Display (LCD) displays prompts and system information on two 16 character lines. If “< >” appears, more information can be accessed by using the arrow (< >) keys. Press [<] to see the previous function or item of information.
  • Page 13 Programming codes from an LCD Keypad: Master Code Press the [ ] key to enter the function list. Scroll (< >) to... Press [5] or [ ]. The display will read... Press (*) for<> Access Codes Enter your current Master Code. The display will read... Enter Master Access Code “01P”...
  • Page 14: Zone Bypassing

    Zone Bypassing The zone bypassing function is used when access is needed to part of the protected area while the system is armed. Zones which are temporarily out of service due to damaged wiring or contacts may be bypassed to allow system arming until repairs can be made. Bypassed zones will not cause an alarm.
  • Page 15: Viewing Trouble Conditions

    Additional Zone Bypassing Features To recall the last set of bypassed zones, press [ ][1][9][9]. Arm the system. The Bypass light will turn on to indicate that zones are bypassed. To clear all bypassed zones, press [ ][1][0][0]. Viewing Trouble Conditions The control panel continuously monitors a number of possible trouble conditions.
  • Page 16: Setting The System Date And Time

    To view troubles from an LCD Keypad: From the Ready state, use the arrow (< >) keys to scroll to the following message. Press [ ] [2] to view the trouble. The message will read... System Trouble (*2) to View< > Use the arrow (<...
  • Page 17: Door Chime Feature

    5. If the panel has any fire zones, activation will cause the alarm signal to sound in a pulsed mode. CAUTION: Do not use an open flame or burning materials to test a smoke or heat detector. Contact your installer for information on safe methods of testing detectors. 6.
  • Page 18: Downloading Enable

    >) keys to scroll through all of the events in the buffer. When you have finished viewing the events, press [#] to exit. Downloading Enable To enable a six-hour downloading window from any system keypad, enter [ ] [6] [Master code] [5]. During this time, the panel will answer incoming downloading calls.
  • Page 19: Fire Escape Planning

    Fire Escape Planning There is often very little time between the detection of a fire and the time it becomes deadly. It is thus very important that a family escape plan be developed and rehearsed. 1. Every family member should participate in developing the escape plan. 2.
  • Page 20 N O T E S...
  • Page 21 N O T E S...
  • Page 22 AVIS: L’étiquette de l’Industrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme à certaines normes de protection, d’exploitation et de sécurité des réseaux de télécommunications. Industrie Canada n’assure toutefois pas que le matériel fonctionnera à la satisfaction de l’utilisateur. Avant d’installer ce matériel, l’utilisateur doit s’assurer qu’il est permis de le raccorder aux installations de l’entreprise locale de télécommunication.
  • Page 24: Limited Warranty

    LIMITED WARRANTY Digital Security Controls Ltd. warrants the original purchaser that for a period of twelve months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use. During the warranty period, Digital Security Controls Ltd. shall, at its option, repair or replace any defective product upon return of the product to its factory, at no charge for labour and materials.