• [4] - System Test
When [4] is pressed the panel will perform the following:
- sound the alarm output for two seconds
- light all lights on the keypad
- sound the keypad buzzer for two seconds
- test the main panel / PC5204 battery
-
send a System Test Reporting code, if programmed (See
Codes") .
• [5] - Enable DLS (Downloading)
When [5] is pressed the panel will turn on the downloading option for 6 hours. During this time the panel
will answer incoming downloading calls (See
• [6] - For future use
• [7] - Enable Background Music
If the intercom is being used to provide background music, press the [6] key to toggle the background
music feature on and off.
Additional Features are available using on the LCD keypad. These features do not have
numbers assigned. Use the arrow keys (< >) to scroll through the [ ] [6] menu and press the
[ ] key to select the following commands.
View Event Buffer
The 128 Event Buffer can be viewed through any LCD keypad (See
Through the LCD
Brightness Control
When this option is selected the keypad will allow you to scroll through 10 different backlight level options.
Use the arrow keys (<>) to scroll to the desired backlight level and press the [#] key to exit.
Contrast Control
When this option is selected the keypad will allow you to scroll through 10 different contrast level options.
Use the arrow keys (<>) to scroll to the desired contrast level and press the [#] key to exit.
Keypad Buzzer Control
When this option is selected the keypad will allow you to scroll through 21 different keypad sounder tone
options. Use the arrow keys (<>) to scroll to the desired keypad beeper level and press the [#] key to exit.
This function can be achieved on LED keypads by holding the [ ] key.
[ ]+[7]
Output Functions
Two Output Functions can be performed at a keypad. They are Utility Output and Smoke Detector Reset.
To activate Utility Output:
Press [ ] [7] [1][Access Code].
The panel will activate all PGM Outputs for 5 seconds programmed as Utility Output for that Partition (See
Section 5.10 "PGM
To activate Smoke Detector Reset:
Press [ ] [7] [2].
The panel will activate all PGM Outputs for 5 seconds programmed as Sensor Reset. This command will
also reset two wire smoke detectors connected to PGM2 programmed as Two Wire Smoke Support (See
Section 5.10 "PGM
[ ]+[8]
Installer Programming
Enter [ ][8] followed by the Installer Code to enter Installer Programming (See
[ ]+[9]
Arming Without Entry Delay
When a Partition is armed with the [ ][9] command the panel will remove the entry delay from the partition.
After the exit delay, Delay 1 and Delay 2 type zones will be instant and Stay/ Away zones will remain
bypassed. (See
A valid access code must be entered after pressing [ ] [9].
[ ]+[0]
Quick Arm/Quick Exit
Quick Arm
If the Quick Arm Enable option is enabled the panel can be armed by entering [ ][0]. This is a useful
method of arming a Partition when someone without a User Code will be required to arm a Partition.
Quick Exit
Quick Exit will allow someone to leave an armed premise through a Delay type zone without having to
disarm and rearm the system.
When [ ][0] is entered, if the Quick Exit Enabled option is enabled, the panel will provide a two minute
window to exit. During this time the panel will ignore the first activation of a Delay type zone. When the
A
D
Keypad") .
Outputs") .
Outputs").
Section 5.1 "Zone
Definitions").
C
O
M
M
Section 5.7 "Communicator - Reporting
Section 5.8
"Downloading") .
Section 5.16.1 "Viewing the Event Buffer
18
A
N
D
Section 4.0 "How to
Program").
S

Advertisement

loading

This manual is also suitable for:

Pc5010