Download Print this page

DSC Power832 Installation Manual page 24

Hide thumbs Also See for Power832:

Advertisement

P
R
O
G
[08]
Standard 24 Hour Fire Zone
When violated the panel will immediately latch the alarm output and communicate to central station. The alarm
will sound for the Bell Cutoff time programmed in Section [005], "System Times" or can be programmed to sound
until a valid code is entered, Section [014], "Second System Option Code, option [8]" .
If a Fire zone is violated it will be displayed on all keypads. Typically this zone is used for pull stations.
[09]
24 Hour Supervisory Zone (with LINKS)
If this zone is violated, whether armed or disarmed, the panel will report to the central station, and log the
zone fault.
[10]
24 Hour Supervisory Buzzer Zone
Whether armed or disarmed, when this zone type is violated the panel will immediately latch the keypad
buzzer until a valid user code is entered and will communicate immediately to the central station.
[11]
24 Hour Burglary Zone
If this zone is violated, whether armed or disarmed, the panel will immediately latch the alarm output and
communicate to the central station. The alarm will sound for the Bell Cutoff time programmed in Section
[005] "System Times" or until a valid user code is entered.
[12]-[20] The following zone definitions operate similar to the 24 Hour Burglary except for System Event output type
and SIA identifier:
[12] 24 Hour Holdup Zone
[13] 24 Hour Gas Zone
[14] 24 Hour Heat Zone
[21]
24 Hour Latching Tamper
If this zone is violated the installer must enter Installer Programming before the panel will allow either
Partition to be armed.
[22]
Momentary Keyswitch Arm Zone
Momentary violation of this zone will alternately arm/disarm the Partition the zone is assigned to. This zone
type should not be programmed as global.
[23]
Maintained Keyswitch Arm Zone
When this zone is violated, the partition it is assigned to will arm. When this zone is secured, the partition
will disarm. This zone should not be programmed as global zone.
NOTE: Wireless zones should not be programmed as keyswitch zones.
[24]
LINKS Answer Zone
If the LINKS1000 cellular communicator is being used it is possible to perform downloading through the
unit if the phone line is disconnected. If this is required connect the RING terminal of the LINKS1000 to this
zone. Refer to the LINKS1000 Installation sheet for more information.
5.2
Zone Attributes
Each zone will operate according to the Zone Definition selected for it (See
Additional zone attributes can be programmed to customize the operation of a zone for a specific
application. The following attributes are programmable by zone:
Attributes for Fire Zones should not be changed from default.
Audible/Silent
Determines whether the zone will activate the alarm output or will be silent.
Pulsed/Steady
Determines if the alarm output will be steady or pulse on for 1 second and off for one second.
Activate Chime
Determines if the zone will activate the chime feature (See
ON/OFF") .
Bypass Enable
Determines if the zone can be manually bypassed (See
R
A
M
D
[15] 24 Hour Medical Zone
[16] 24 Hour Panic Zone
[17] 24 Hour Emergency Zone
(Non-medical emergency only)
E
S
C
R
I
Section 3.4 "[ ] Commands, [ ] [4] Door Chime
Section 3.4 "[ ] Commands, [ ] [1] - Zone
24
P
T
I
O
N
[18] 24 Hour Sprinkler Zone
[19] 24 Hour Water Flow Zone
[20] 24 Hour Freezer Zone
Section 5.1 "Zone
Definitions") .
Bypass") .
S

Advertisement

loading

This manual is also suitable for:

Pc5010