To delete a community, first touch the community name to be deleted. In the screen that appears
(similar to Figure 35), click DELETE at the bottom of the screen.
7.2.7.2.2
SNMP
Selecting this check box allows SNMP packets to be accepted from any host. You also have the option of
adding hosts (see Figure 36). Adding or deleting hosts is performed in the same manner as adding or
deleting communities—see section 7.2.7.2.1.
7.2.7.2.3
SNMP
An SNMP trap is a destination to which the Centric will send alarm notifications using the SNMP protocol.
For each destination, an IP address and a port must be specified.
Adding or deleting trap destinations is performed in the same manner as adding or deleting communities—
see section 7.2.7.2.1.
Note: Centric supports the UPS MIB (Management Information Base) standard.
7.2.7.3

SERIAL COMMUNICATION (OPTIONAL FEATURE)

Serial communication is an optional feature, available by special order.
This option enables serial communication between the Centric and an external device. Indicate the port to
be used and the baud rate. Choose one of the ports from the list.
If your system includes this option, the serial communication connector is labeled "RS232" and is located
on the left side of the static switch on the rear side of the UPS.
Note: If the serial communication option is ordered as an add-on to an existing system, the physical
connection details may be other than described above.
7.2.7.4
MODBUS (OPTIONAL FEATURE)
The ability to use a Modbus link with the Centric is an optional feature, available by special order. A
password may be required to use this feature. If you do not have the appropriate password, contact your
distributor or sales agent.
Two types of Modbus links can be defined between the Centric and another device on the network: a serial
link or a TCP/IP link. The two types of links are not mutually exclusive. In either case, with regards to
Modbus, the Centric is a slave device to the Modbus master located elsewhere on the Modbus
communication network. The Centric will respond to queries from the Modbus master.
CENTRIC 3x480, User Guide, rel. 1.7
G
AMATRONIC
> ACCEPT SNMP PACKETS FROM THESE HOSTS
CONFIGURATION
> TRAP DESTINATIONS
CONFIGURATION
Figure 37: Defining serial communication parameters
E
I
L
LECTRONIC
NDUSTRIES
.
TD
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Centric 240 kwCentric 120 kw

Table of Contents