Default: Off
[Terminal 3]
Determine how to use terminal 3.
Off: Not used.
Alarm input: Receives alarms. When "Alarm input" is selected, a pull-down menu for "Close" and
"Open" is displayed.
Close: An alarm is detected when the terminal status is changed to "Close".
Open: An alarm is detected when the terminal status is changed to "Open".
AUX output: AUX output will be supplied. The [AUX] buttons will be displayed on the "Live" page.
Black & white output: Turns the output on when the image is switched to black & white mode.
Default: Off
IMPORTANT
In order for the EXT I/O terminals to detect alarm inputs when the terminal status is changed from Open
to Close (On) or from Close to Open (Off), about 100 ms or more is needed. Alarm inputs received
during the duration specified in [Alarm deactivation time] are not detected.
Note
AUX is a camera terminal that allows users to operate (Open/Close) arbitrarily from the "Live" page.
For example, an operator can remotely control lights in a place where the camera is installed by
connecting the terminal to the light controller.
Refer to the installation guide for further information about input/output rating of each terminal.
[VMD alarm]
When clicking "VMD >>", the [VMD area] tab of the "Alarm" page will be displayed. (®page 116)

[Command alarm]

Select "On" or "Off" to determine whether or not to receive the command alarm.
The command alarm is the function that provides notification of a Panasonic protocol alarm from the other
cameras. When "On" is selected, alarm actions will be performed between multiple cameras.
Default: Off
[Originating port number]
Select a port number to be used to receive the command alarm.
Available range: 1-65535
Default: 8181
The following port numbers are unavailable since they are already in use.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 554, 995, 10669, 10670, 59000-61000
[Alarm deactivation time]
Configure the duration that detections won't be made after an alarm is detected. For example, by using this
function you can prevent E-mail from being sent too often when E-mail notifications are configured to be sent
to cellular phones when an alarm is detected.
5s/ 10s/ 30s/ 1min/ 3min/ 5min/ 10min
Default: 5s
Note
The duration that alarm detections are not made can be managed for each type of alarm. For example,
during the time when detections for command alarms are not made, detections for VMD alarm can be
made.