Off: Not used.
Alarm input: Receives alarms. When "Alarm input" is selected, a pull-down menu for "Close" and
"Open" is displayed.
Close: An alarm is detected when the terminal status is changed to "Close".
Open: An alarm is detected when the terminal status is changed to "Open".
Alarm output: Alarm output will be carried out according to the settings for "Alarm output terminal
setup" (®page 118).
Default: Off
[Terminal 3]
SFx311
Determine how to use terminal 3.
Off: Not used.
Alarm input: Receives alarms. When "Alarm input" is selected, a pull-down menu for "Close" and
"Open" is displayed.
Close: An alarm is detected when the terminal status is changed to "Close".
Open: An alarm is detected when the terminal status is changed to "Open".
AUX output: AUX output will be supplied. The [AUX] buttons will be displayed on the "Live" page.
Default: Off
IMPORTANT
In order for the EXT I/O terminals to detect alarm inputs when the terminal status is changed from Open
to Close (On) or from Close to Open (Off), about 100 ms or more is needed. Because alarms cannot
be detected for about 5 seconds after a detection is made, alarm inputs received within about 5 seconds
after an alarm is detected are not detected.
Note
AUX is a camera terminal that allows users to operate (Open/Close) arbitrarily from the "Live" page.
For example, an operator can remotely control lights in a place where the camera is installed by
connecting the terminal to the light controller.
Refer to the installation guide for further information about input/output rating of each terminal.
[VMD alarm]
When clicking "VMD >>", the [VMD area] tab of the "Alarm" page will be displayed. (®page 128)
[Audio detection alarm]
When "Audio detection>>" is clicked, the [Audio detection] tab will be displayed. (®page 130)

[Command alarm]

Select "On" or "Off" to determine whether or not to receive the command alarm.
The command alarm is the function that provides notification of a Panasonic protocol alarm from the other
cameras. When "On" is selected, alarm actions will be performed between multiple cameras.
Default: Off
[Originating port number]
Select a port number to be used to receive the command alarm.
Available range: 1-65535
Default: 8181
The following port numbers are unavailable since they are already in use.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 554, 995, 10669, 10670, 59000-61000
SFx310
SPN311
SPN310
SFx311
SPN311
13 Configure the alarm settings [Alarm]
SPW311L
SPN531
SPW311L
SPN531
SPW531L
SPW531L
SFN310
SPN310
Operating Instructions
117

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents