Configure The Settings Relating To The Alarm Action [Alarm] - Panasonic WV-SFV781L Operating Instructions Manual

Hide thumbs Also See for WV-SFV781L:
Table of Contents

Advertisement

13 Configure the alarm settings [Alarm]
13 Configure the alarm settings [Alarm]
The settings relating to alarm occurrences such as settings for the alarm action at an alarm occurrence or
alarm images, the VMD area settings, and the alarm occurrence notification can be configured on this page.
The "Alarm" page has the [Alarm] tab, the [VMD area] tab, and the [Notification] tab.
13.1 Configure the settings relating to the alarm
action [Alarm]
Click the [Alarm] tab on the "Alarm" page. (®page 44, page 46)
The settings relating to the alarm can be configured in this section. Refer to page 110 and page 108 for further
information about the settings relating to the alarm images and the alarm output terminal.
Alarm
[Terminal 1]
Determine how to use terminal 1.
Off: Not used.
Alarm input: Receives alarms. When "Alarm input" is selected, a pull-down menu for "Close" and
"Open" is displayed.
Close: An alarm is detected when the terminal status is changed to "Close".
Open: An alarm is detected when the terminal status is changed to "Open".
Black & white input: Receives the black & white switchover input. (When the input is set to On, the black
& white mode is activated.)
Default: Off
[Terminal 2]
Determine how to use terminal 2.
Off: Not used.
Alarm input: Receives alarms. When "Alarm input" is selected, a pull-down menu for "Close" and
"Open" is displayed.
Close: An alarm is detected when the terminal status is changed to "Close".
Open: An alarm is detected when the terminal status is changed to "Open".
Alarm output: Alarm output will be carried out according to the settings for "Alarm output terminal
setup" (®page 108).
106
Operating Instructions

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wv-spv781lWv-spv781lpj

Table of Contents